  • 300°C (PF 30 to PF 200) or 250°C (PF 400, PF 800) maximum operating temperatures
  • 28 to 910 litre chamber volumes
  • Equipped with the R38 digital PID temperature controller (PF 30 to PF 200)
  • Carbolite Gero 301 controller, with single ramp to set-point & process timer (PF 400 & PF 800)
  • Fan convection for rapid heating & recovery & excellent uniformity
  • Chemically resistant stainless steel liner
  • Two nickel-chrome plated wire shelves (The PF 400 is supplied with 3 wire shelves, the PF 800 with 3 perforated stainless steel shelves)
  • Lever latch door & airtight silicone seal
  • Compliant with safety standard BS EN 61010-2-010:2003
  • Over-temperature protection (recommended to protect valuable contents & for unattended operation)
  • A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications
  • Access port for independent thermocouple
  • Accessory shelves & runners
  • Heavy duty reinforced base and shelves
  • Cable entry ports
  • Variable speed fan control
  • Stoving & curing options for extraction of small volumes of volatile solvents (not compatible with viewing window option)
  • Viewing window (not compatible with stoving & curing option)
  • Interior light (not compatible with stoving & curing option)
  • Air exhaust fan
  • Moisture extraction option (comprising sealed seams and air exhaust fan)
  • Stacking frame to enable units to be stacked one upon another
  • Lockable door
  • Door switch to isolate elements and fan
  • Fixed or castor mounted floor stands
  • Low voltage options for use below 220 V
  • Routine spares kit

PF30

  • Max temp (°C) : 300
  • Min temp (°C) : Ambient +30
  • Volume (litres) : 28
  • Temp stability (°C) : ±0.2
  • Temp uniformity (°C) : ±5.0 @ 300°C
  • Heat-up time (mins) : 40
  • Recovery time (mins) : 4
  • Dimensions:
  • Internal H x W x D (mm) : 300 x 290 x 320
  • Dimensions:
  • External H x W x D (mm) : 470 x 665 x 470
  • Shelves fitted / accepted : 2 / 3
  • Shelf loading each / total (kg) : 10 / 20
  • Optional heavy duty reinforced base max. weight (kg) : 40
  • Optional heavy duty shelves max. quantity : 2
  • Optional heavy duty shelves max. weight / shelf (kg) : 20
  • Configuration : Bench-top
  • Air changes / hr : 50 / 360*
  • Max power (W) : 1000
  • Holding power (W) : 560
  • Weight (kg) : 37

PF60

  • Max temp (°C) : 300
  • Min temp (°C) : Ambient +30
  • Volume (litres) : 66
  • Temp stability (°C) : ±0.2
  • Temp uniformity (°C) : ±5.0 @ 300°C
  • Heat-up time (mins) : 36
  • Recovery time (mins) : 4
  • Dimensions:
  • Internal H x W x D (mm) : 400 x 390 x 420
  • Dimensions:
  • External H x W x D (mm) : 570 x 765 x 570
  • Shelves fitted / accepted : 2 / 5
  • Shelf loading each / total (kg) : 10 / 30
  • Optional heavy duty reinforced base max. weight (kg) : 60
  • Optional heavy duty shelves max. quantity : 3
  • Optional heavy duty shelves max. weight / shelf (kg) : 20
  • Configuration : Bench-top
  • Air changes / hr : 21 / 153*
  • Max power (W) : 1500
  • Holding power (W) : 775
  • Weight (kg) : 55

PF120

  • Max temp (°C) : 300
  • Min temp (°C) : Ambient +30
  • Volume (litres) : 127
  • Temp stability (°C) : ±0.2
  • Temp uniformity (°C) : ±5.0 @ 300°C
  • Heat-up time (mins) : 35
  • Recovery time (mins) : 4
  • Dimensions:
  • Internal H x W x D (mm) : 500 x 490 x 520
  • Dimensions:
  • External H x W x D (mm) : 670 x 865 x 670
  • Shelves fitted / accepted : 2 / 9
  • Shelf loading each / total (kg) : 10 / 40
  • Optional heavy duty reinforced base max. weight (kg) : 80
  • Optional heavy duty shelves max. quantity : 3
  • Optional heavy duty shelves max. weight / shelf (kg) : 25
  • Configuration : Bench-top
  • Air changes / hr : 11 / 79*
  • Max power (W) : 2000
  • Holding power (W) : 900
  • Weight (kg) : 74

PF200

  • Max temp (°C) : 300
  • Min temp (°C) : Ambient +30
  • Volume (litres) : 230
  • Temp stability (°C) : ±0.2
  • Temp uniformity (°C) : ±5.0 @ 300°C
  • Heat-up time (mins) : 42
  • Recovery time (mins) : 5
  • Dimensions:
  • Internal H x W x D (mm) : 750 x 590 x 520
  • Dimensions:
  • External H x W x D (mm) : 920 x 965 x 670
  • Shelves fitted / accepted : 2 / 15
  • Shelf loading each / total (kg) : 10 / 50
  • Optional heavy duty reinforced base max. weight (kg) : 100
  • Optional heavy duty shelves max. quantity : 4
  • Optional heavy duty shelves max. weight / shelf (kg) : 25
  • Configuration : Bench-top
  • Air changes / hr : 6 / 44*
  • Max power (W) : 2700
  • Holding power (W) : 1180
  • Weight (kg) : 96

PF400

  • Max temp (°C) : 250
  • Min temp (°C) : Ambient +30
  • Volume (litres) : 460
  • Temp stability (°C) : ±0.2
  • Temp uniformity (°C) : ±5.0 @ 250°C
  • Heat-up time (mins) : 85
  • Recovery time (mins) : 25
  • Dimensions:
  • Internal H x W x D (mm) : 1500 x 605 x 510
  • Dimensions:
  • External H x W x D (mm) : 1835 x 1025 x 1100
  • Shelves fitted / accepted : 3 / 14
  • Shelf loading each / total (kg) : 10 / 75
  • Optional heavy duty reinforced base max. weight (kg) : 150
  • Optional heavy duty shelves max. quantity : 5
  • Optional heavy duty shelves max. weight / shelf (kg) : 25
  • Configuration : Floor-standing
  • Air changes / hr : 30
  • Max power (W) : 6000
  • Holding power (W) : 2200
  • Weight (kg) : 200

PF800

  • Max temp (°C) : 250
  • Min temp (°C) : Ambient +30
  • Volume (litres) : 910
  • Temp stability (°C) : ±0.2
  • Temp uniformity (°C) : ±5.0 @ 250°C
  • Heat-up time (mins) : 100
  • Recovery time (mins) : 30
  • Dimensions:
  • Internal H x W x D (mm) : 1500 x 1200 x 510
  • Dimensions:
  • External H x W x D (mm) : 1835 x 1615 x 1100
  • Shelves fitted / accepted : 3 / 7
  • Shelf loading each / total (kg) : 10 / 100
  • Optional heavy duty reinforced base max. weight (kg) : 225
  • Optional heavy duty shelves max. quantity : 5
  • Optional heavy duty shelves max. weight / shelf (kg) : 75
  • Configuration : Floor-standing
  • Air changes / hr : 15
  • Max power (W) : 9000
  • Holding power (W) : 3500