Anybus Interface Master - Model AS -CC-Link Slave X-Gateway
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between AS-Interface and CC-Link networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Master on the AS-Interface network and as a Slave on the CC-Link network. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
- Fast copying of cyclic I/O data between two networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Supports up to a maximum of 512 bytes of Input and Output data in each direction
- Powerful Master interface for AS-Interface eliminates the need for a PLC controller
- Optional control and status information added to the I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
An Anybus X-gateway with an integrated AS-Interface M4 Master interface can be used when there is no existing AS-Interface controlling PLC.
- Complies to AS-Interface 3.0 specification
- Controls up to 62 AS-Interface slaves
- Optional Live List of the active status of the connected slaves
- Supports Combined Transaction Types 1, 2, 3, 4 and 51
- Up to 248 digital inputs and 186 digital outputs
- Up to 124 (16-bit) analog values
- AS-Interface baudrate 167 kbit/s
- Synchronous I/O (optional)
- On-board configuration button
- 1x D-sub 9-pin male connector (RS-232) for terminal-based monitoring and configuration
- 2x 2-pin 5,08 Phoenix plug connectors
CC-Link Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.
- Complete CC-Link slave Version 1 and 2 functionality
- CC-Link Conformance BAP-05027-B specification
- Transparent CC-Link communication (Standard Mode)
- PLC Profile compliant communication (PLC profile mode)
- Max. 896 bits/128 words (368 bytes) of I/O data in each direction
- Supports CC-Link baudrates 156 kbit/s – 10 Mbit/s
- Up to 4 occupied stations
- Up to 8 extension cycles (version 2 only)
- CC-Link configuration via on-board switches or via .CSP file
- 1x 5-pin, 5.08 Phoenix plug network connector
- Dimensions (L•W•H) : 114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
- Weight: 400g or 0,880 lbs
- Operating temperature: -25 to +65 °C or -13 to +149 °F
- Storage temperature: -40 to +85 °C or -40 to +185 °F
- Power supply: 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector
- Current consumption: max. 400mA (Typical 200mA)
- Enclosure material : Aluminium and plastic
- Installation position: Vertical / Flat*
- Galvanic isolation: YES, on both BUS/Ethernet side
- Mechanical rating: IP20, NEMA rating 1
- Mounting: DIN-rail (EN 50022 standard)
- I/O configuration: via USB port with Anybus Configuration Manager software
- Certifications: CE, CULUS, RoHS