Continental Control Systems, LLC (CCS), A member of Socomec Group

CCSModel TCL-B Series -Current Transformers

SHARE

The TCL-B series current transformers measure AC line current in circuits up to 600 Vac and nominal currents up to 100 amps.

Most popular related searches
  • Revenue Grade accuracy (0.2% or 0.3%)
  • Low-cost
  • Opening: 0.50 inch (12.8 mm)
  • Milliamp output accuracy: 0.2%
  • Millivolt output accuracy: 0.3%
  • Rated current: 50, 100 amps
  • UL Listed (UL 2808, XOBA)

The TCL-B series current transformers offer Revenue Grade accuracy in circuits up to 600 Vac and nominal currents up to 100 amps.

  • Revenue Grade accuracy (0.2% or 0.3%)
  • Solid-core (toroidal)
  • Compact
  • Low-cost
  • Opening window: 0.50 inch (12.8 mm)
  • Milliamp output accuracy: 0.2%
  • Millivolt output accuracy: 0.3%
  • Rated current: 50 and 100 amps
  • UL Listed (UL 2808, XOBA)
  • Accuracy
  • Millivolt Output Accuracy (% of reading): TCL-B-050 andTCL-B-100
  • Typical Accuracy:
    • ±0.3% from 1% to 120% of rated current
    • In the following graphs, a positive phase angle error indicates that the output of the CT leads the primary current.
  • Phase angle:
    • ±0.15 degrees (9 minutes) from 20% to 120% of rated current
    • ±0.33 degrees (20 minutes) from 1% to 20% of rated current
    • IEEE C57.13 accuracy: class 0.6
    • IEC 60044-1 accuracy: class 0.5S
  • Milliamp Output Accuracy (% of reading): TCL-B-100/40mA
    • Typical Accuracy:
      • ±0.2% from 1% to 120% of rated current
      • In the following graphs, a positive phase angle error indicates that the output of the CT leads the primary current.
    • Phase angle:
      • ±0.15 degrees (9 minutes) from 20% to 120% of rated current
      • ±0.33 degrees (20 minutes) from 1% to 20% of rated current
      • IEEE C57.13 accuracy: class 0.6
      • IEC 60044-1 accuracy: class 0.5S
  • Electrical
    • Line Frequency: 50 to 60 Hz
    • Maximum Continuous Primary Current: 250 amps
    • Maximum Voltage: 600 Vac
    • Overvoltage and Measurement Categories: CAT III: 600 Vac
    • Lead Wire: 2.4 m (8 feet), 18 AWG, 105°C, 600 V, twisted pair
    • Ouput:
      • Milliamp Ouput: Current output
        • Output Current: 40 mA at 100 A primary current
        • Output Protection: includes internal clamp zener at 13 Vac
      • Millivolt Output: Voltage output, integral burden resistor
        • Output Voltage at Rated Amps: 0.33333 Vac (one-third volt)
        • Output Protection: includes internal burden resistor
  • Environmental
    • Operating Temperature: –40°C to +85°C (–40°F to 185°F)
    • Operating Humidity: Non-condensing, 0 to 100% relative humidity (RH)
    • Operating Altitude: Up to 3000m
    • Pollution: POLLUTION DEGREE 2
    • Indoor Use:
    • Suitable for indoor use
    • Outdoor Use:
    • Suitable for outdoor use when mounted in a NEMA 3R or 4 (IP 66) rated enclosure, provided the ambient temperature will not exceed 85°C (185°F)
  • Mechanical
    • Width: 1.46 inches (37.0 mm ± 0.3 mm)
    • Height: 1.61 inches (41.0 mm ± 0.3 mm)
    • Thickness: 0.55 inches (14.0 mm ± 0.2 mm)
    • Opening: 0.51 inches (13.0 mm ± 0.2 mm)
    • Weight: 125 g
  • Regulatory
    • CE
    • UL: UL listed, XOBA, UL 2808, CAN/CSA-C22.2 No. 61010-1, E363660
    • RoHS Compliant
  • Accuracy:  ±0.3% from 1% to 120% of rated primary current
  • Primary Rated Amps:  50 or 100 amps/0.333 Vac
  • Maximum Primary Current:  250 amps
  • Accuracy Class:  IEEE / ANSI C57.13  class 0.3
  • CE Accuracy:  IEC 60044-1 class 0.5S
  • CE Safety: CE
  • RoHS Compliant :•
  • UL USA:
  • UL listed, XOBA, UL 2808
  • Standard Lead Length:
  •  8 ft. (2.4 meters), 18 AWG PVC, 105°C, 600 V
  • Phase Angle:  ±0.15 degrees (9 minutes) from 20% to 120% of ratedc
  • urrent; ±0.33 degrees (20 minutes) from 1% to 20% of rated current
  • Operating Temperature:  −40°C to 85°C (−40°F to 185°F)
  • Line Frequency:  50/60 Hz
  • Approx. Weight:  117   g r a m s
  • Srialized certificate of calibration provided