CBF S.r.l.

CBFModel VNR4008-C -Check Valve, Cartridge Type

SHARE

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C, Recommended viscosity 10 ÷ 420 cSt, Working temperature -20 ÷ +90 °C, Absolute filitration 25 μm,

Most popular related searches
  • Maximum flow : 40 l/min
  • Maximum pressure : 350 bar
  • Cracking pressure : 
    • 0,5 bar
    • 2 bar
    • 3 bar
    • 5 bar
  • Installation torque : 27÷30 Nm