Breas Medical AB
- Home
- Companies
- Breas Medical AB
- Products
- Clearway - Model 2 - Second Generation ...
Clearway - Model 2 -Second Generation MI-E Device
FromBreas Medical AB
Introducing the new Clearway 2 with TreatRepeat® The second-generation MI-E device by Breas incorporates the latest technology to bring effective and accurate treatment for patients requiring airway clearance and cough assistance. TreatRepeat function allows clinicians to manually deliver different numbers of insufflations and exsufflations and then save the treatment they have just delivered to the device to be repeated automatically. Helping to improve accuracy and speed of titration and set-up.
Most popular related searches
ADVANCED TITRATION TECHNOLOGY
- Unique to the Clearway 2 – TreatRepeat®
- Intuitive touchscreen user interface
- Hand-held remote manual switch with start/stop function
MULTIPLE MODE OPTIONS
- Programmable automatic modes
- Dedicated IPPB mode
- Manual mode
ENHANCED PATIENT SYNCHRONY
- TreatRepeat® to help improve accuracy and speed of titration and set-up
- iTrigger® − built on the Breas patented eSync algorithm
- Synchrony Beep® to aid patient-device synchrony
Settings / Performance
- Modes : Manual, Basic Auto, Program Mode, IPPB, NIV
- Device Modes : Home, Clinical (Locked/Unlocked)
- Profiles : 4 settable profiles
- Insufflation Pressure : 3 cm H2O to 70 cm H2O
- Exsufflation Pressure : −3 cm H2O to −70 cm H2O
- Insufflation Time : 0.5 to 5 seconds
- Exsufflation Time : 0.5 to 5 seconds
- Pause Time : 0.5 to 5 seconds
- Flow Options (MI-E) : 1−10 (10−100% of Ti max 4 seconds)
- Flow (IPPB) : 20 L/min to 120 L/min
- Inspiratory Trigger : Off or 1 to 10
- Oscillations Frequency : Insufflations and or Exsufflations, Off – 1 – 20 Hz
- Oscillations Amplitude : 1 cm H2O to 10 cm H2O
- Displayed Data : Cough Peak Flow, Insufflation Volume, Pressure, Flow, SpO2, Heart Rate Sessions Used, Average Session Duration
- Waveforms : Pressure
- Trend and Statistical Data via PC Software : Cough Peak Flow, Insufflation Volume, Use, SpO2, Heart Rate
- Mains Supply : 100 to 240 V AC
- Internal Battery : >30 min in MI-E modes (based on settings of +40/ -45cmH2O, Ti/Te/P 2 seconds)
- Alarms : Circuit Disconnection, Running on Battery Power, External Battery Fault, High Pressure Alarm, Internal Over Temperature Alarm, Low Battery, Low Memory Battery, Machine Fault, Low SPO2 Reading, High SO2 SpO2 Sensor Disconnect, High/Low Heart Rate, Power Fail
- W x H x D : 285 x 285 x 195 mm
- Weight : 3.85 kg
- Noise Level (at 10 cm H2O Constant Pressure) : Sound Level at 70 cm H2O in Manual Mode Less Than 74 dB(A) Measured at 1 meter
- Built-in Connectivity : Ethernet, USB, SD card
- Compatible Software : Prepared for Breas Cloud Service
- Plug-and-Play Accessories : SpO2, Hand Held Remote Start/Stop and Manual Switch, Manual Foot Pedal Switch
- Circuits : Disposable circuit with bacterial filter no leak port for MI-E modes and disposable circuit with bacterial filter and leak port for IPPB and NIV modes