Con-Trex - Model LP -Isokinetic Leg Press for Testing and Training
The CON-TREX LP leg press is an isokinetic testing and training machine for the entire leg extensor and flexor chain. It can provide metered, measurable forces from a few N to 6000 N at speeds of up to 1 m/sec. Separate footplates allow unilateral training (on the left or right), bilateral training with both legs, or alternating mode. The adjustable footplate fixtures can be varied for selective testing and improvement of ankle joints in various positions. The inclination of the backrest can be electrically lowered to the horizontal position, the seat angle is synchronized with the adjustment of the backrest. The low seat height facilitates placement of patients with reduced mobility.
The high level of precision of the metered, measurable forces and the exceptional properties of the motion monitor through the drive system produce an extremely versatile area of application on a minimum workspace of just 1.8 x 2.5 meters including the control module.
Due to the functional motion, the entire muscle chain of the lower limbs is strengthened, while the coordination is simultaneously improved and the joint stability increased. The optimally adjusted load and strain of the (atrophied) musculature beyond the entire radius of motion can bring about a very sharp increase in the muscle strength and a significant improvement to coordination. All of this occurs without any excessive strain on the joint, especially in physiologically awkward positions.
The human kinetics software allows easy separation of databases, thereby enabling different internal departments or scientific areas within the same facility to work independently. The presentation of the numerous report designs can be customised. Export to other data processing programs is done easily via the ASCII interface. Anonymisation of the data for scientific work is easily possible.
The detailed online help provides direct notes on the current menu item or the operation being performed, with images and graphics. Above all, the detailed information on the numerous movement performances clarifies both the positioning of the subject / patient and the use of the required adapters.
Therapy information
CON-TREX® can be used in early diagnostic and preventative therapy for injuries to the musculoskeletal system in out-patient rehabilitation and in the clinic. It is also used in scientific research and performance optimisation and facilitates the careful and specific analysis of problems and thus the highly efficient training of top athletes.
CON-TREX® machines are suited to measurement and analysis thanks to the high levels of precision and are thus especially well-suited to scientific use. In training and therapy, they aim to improve muscle capabilities (in both the strength and stamina areas) as well as sensorimotor skills. Thanks to its versatile measuring capabilities and the intuitive exercise software, CON-TREX® is excellently suited to the following applications:
CON-TREX® enables the early diagnosis and prevention of damages or injuries to the musculoskeletal system in out-patient rehabilitation and in clinical use.
Diagnosis and rehabilitation of musculoskeletal deficiencies
Muscular disbalances can disrupt the ideal sequence of movements and may have damaging effects on the joints or, depending on the type of sport, can even be desirable or required. CON-TREX® helps to record, detect and analyse these disbalances. In addition, CON-TREX® machines can be used to efficiently eliminate muscular disbalances. One particular benefit is in the fact that the tested movement can be trained at the same time.
Joint replacement
CON-TREX® machines can be used in the area of geriatric rehabilitation after artificial joint replacement in particular. Even at very low available muscular strength patients can actively train and improve their muscularity at a sensible speed of motion. This means that the loss of strength is kept to a minimum and the mobility of the joints either remains the same or is improved.
- high-precision isokinetic mode
- ballistic mode
- active compensation of gravity
- unique combined load types
- sampling rate of 4000 Hz for highest precision
- play-free drive train
- EMG synchronisation
- three-level safety concept
- individually customisable report
