Cytek Aurora64 Fluorescence Channels System

SHARE

A prodigy incorporating a unique combination of patent-pending innovative technologies that takes flow cytometry to the next level of performance and flexibility. With up to five lasers, three scattering channels, and 64 fluorescence channels, the Aurora suits every laboratory’s needs, from simple to high complexity applications. A paradigm shifting optical design provides unprecedented flexibility, enabling the use of a wide array of new fluorochrome combinations without reconfiguring your system for each application. The state-of-the-art optics and low-noise electronics provide excellent sensitivity and resolution. Flat-top beam profiles, combined with a uniquely designed fluidics system, translate to outstanding performance at high sample flow rates.

Most popular related searches

The end result is a system that delivers high quality data where rare and dim populations are easily resolved, regardless of assay complexity.

SpectroFlo® Software offers an intuitive workflow from QC to data analysis with technology-enabling tools that simplify running applications.

The Cytek team has reimagined every aspect of cytometry hardware and software to deliver an instrument that fulfills every scientist`s needs.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Maximum Channels

64 fluorescence channels of detection over the full emission spectra.

Maximum Colors

Beyond 30 colors demonstrated including fluorochromes with emission spectra in close proximity to each other.

Maximum Sensitivity

Sensitivity redefined using state-of-the-art optics and low-noise electronics.

Maximum Flexibility

No changing optical filters for any fluorochrome.

Use any commercially available fluorochrome excited by the onboard lasers.

Maximum Accessibility

A powerful, high value system that is accessible to a wide range of users.

OpticsExcitation OpticsOptical Platform

Aurora contains a fixed optical assembly with the capacity to be configured with up to five spatially separated laser beams. Laser delays are automatically adjusted during instrument QC.

Lasers

Base model three-laser configuration: 405 nm: 100 mW, 488 nm: 50 mW, 640 nm: 80 mW
Available laser upgrades: 355 nm: 20 mW, 561 nm: 50 mW

Beam geometry

Flat-Top laser beam profile with narrow vertical beam height optimized for small particle detection.

Emission OpticsEmission Collection

Fused silica cuvette coupled to high NA lens for optimum collection efficiency to optical fibers.

Forward and Side Scatter Detection

FSC: high-performance semiconductor detector with 488nm bandpass filter

SSC: two high-performance semiconductor detectors with 405nm and 488nm bandpass filters

Fluorescence Detectors

Proprietary high sensitivity Coarse Wavelength Division Multiplexing (CWDM) semiconductor array per laser enabling more efficient spectrum capture in the 365-829 nm range. No filter changes required for any fluorochrome excited by the 355 nm, 405 nm, 488 nm, 561 nm, 640 nm lasers.

Standard Optical Configuration

Violet detector module: 16 channels unevenly spaced bandwidth from 420-829 nm.

Blue detector module: 14 channels unevenly spaced bandwidth from 498-829 nm.

Red detector module: 8 channels unevenly spaced bandwidth from 652-829 nm.

4 and 5 Laser Options:
Yellow-Green detector module: 10 channels unevenly spaced bandwidth from 567-829 nm.
Ultraviolet detector module: 16 channels unevenly spaced bandwidth from 365-829 nm.

FluidicsSample Flow Rates

Low: 15 µL/min, Medium: 30 µL/min, High: 60 µL/min, Plate high-throughput mode: 100 µL/min

Fluidic Modes

Long clean, SIT flush, Purge filter, Clean flow cell

Manual Sample Input Formats

12x75mm polystyrene and polypropylene tubes

Standard Fluidic Reservoirs

4L fluid container set with level-sensing provided. Compatible with 20L sheath and waste cubitainers.

Volumetric Sensor

Volumetric measurement during sample recording enables calculation of counts per µL for any gated population.

Plate Loader Option

96-well microtiter plate capability

Throughput time 35 minutes at High Throughput mode sampling 7 µL/well

Plate stage temperature: 4-30°C

Plate Loader Carryover

Default mode: ≤0.3%, Low Carryover mode: ≤0.1%, High Throughput mode: ≤1%

PerformanceFluorescence Sensitivity

FITC: ≤35 MEFL, PE: ≤10 MEFL, APC: ≤10 MEFL, Pacific Blue: ≤25MEFL

* measurements based on an average from two systems, one three lasers and one five lasers, and performed using SPHERO Rainbow Calibration Particle (RCP-30-5A) based on its peak emission channel.

Fluorescence Linearity

FITC R2 ≥0.995 / PE R2 ≥0.995

Forward and Side Scatter Resolution

Performance is optimized for resolving lymphocytes, monocytes, and granulocytes.

Side Scatter Resolution

Capable of resolving 0.2 µm beads from noise.

Carryover

≤0.1%

Data Acquisition Rate

35,000 events/s*

* Three-laser system

Software SpectroFlo®Software

Live unmixing during acquisition

Developed specifically to streamline assay setup, data acquisition, and file export.

Automated QC module

Autofluorescence extraction

Raw and Unmixed FCS 3.1 files

ElectronicsSignal Processing

Digital signal processing with automatic window gate adjustment.

22-bit 6.5 log decades.

Threshold using any single parameter or combination of parameters.

Pulse Shape Parameters

Pulse Area and Height for every parameter. Width for scatter parameters and one fluorescence parameter for each laser.

Workstation

Workstation specifications may vary between laser configuration; below is for three-laser configuration.

Operating System

Windows® 10 Pro 64-bit

Processor

Intel® Core i7 processor, 3.6 GHz

RAM

16GB

Hard Drive

500GB SSD / 1TB SATA

Video Processor

NVIDIA® GeForce

Monitor

32” UHD 4K Monitor

Installation Requirements

Dimensions (W x D x H)

Instrument Dimensions

Without loader: 54 x 52 x 52 cm
With loader: 58.4 x 62 x 52 cm

Instrument Weight

Instrument weight (4 lasers): 80 kg
Loader weight: 13kg

Computer Dimensions

29.1 x 9.25 x 34.4 cm

Recommended Workspace

157 x 71 x 132 cm

Room RequirementsPower

100-240V, 50/60 Hz, 2A max

Heat Dissipation

500W with all solid-state lasers

Temperature

15–28°C

Humidity

20%-85% relative non-condensing

Air filtering

No excessive dust or smoke

Lighting

No special requirements

Regulatory Status

For Research Use Only. Not for use in diagnostic or therapeutic procedures.