Hangzhou Zeal Instruments Science & Technology Co.,Ltd

ZealModel DSC-40AE -Differential Scanning Calorimeter

SHARE

Designed based on the principle of tower-type heat flow method, this is a standard thermal analysis instrument that measures the heat flow difference per unit time between the sample and the reference sample under programmed temperature control, varying with temperature or time.

Most popular related searches
Test Parameters

Thermodynamic and Kinetic Analysis


Applicable Fields

Polymers, Biomedicine, Inorganic Non-metallic Materials, etc.


Keywords

DSC Differential Scanning Calorimetry, Differential Thermal Analyzer, DSC Instruments, DSC Chemistry

  • Utilizes tower-type heat flow technology to enhance instrument resolution and sensitivity.
  • Silver furnace body ensures higher heat transfer efficiency, reducing cross-interference between reference and sample.
  • Employs specialized algorithms for precise modulation of temperature and heat flow signals, enabling accurate measurement of specific heat capacity, exothermic reactions, etc.
  • Features both ramp and isothermal temperature control modes.
  • Capabilities include DSC Onset Point, Start Set Point, Endset Point, baseline, heat flow peak, glass transition temperature, peak area, enthalpy of absorption/release, peak temperature, extrapolated onset temperature, specific heat, etc.
  • Data acquisition rate of 50Hz, significantly improving sensitivity and resolution.
  • Nickel-chromium substrate enhances high-temperature oxidation resistance, sensitivity, and dynamic response.
  • Optimized structural design ensures reliable baseline stability and improved signal-to-noise ratio.
  • Equipped with a high-definition touchscreen for easy operation.
  • Standards——GB/T 22232, GB/T 28724, GB/T 28723, GB/T 19466.2, ASTM E2253, ASTM E793, ASTM E1269

Operating Environment: 5°C to 40°C, <85% RH

Temperature Control Range: RT to 600°C

Heating Scan Rate: 0.1K/min to 200K/min

Scan Rate Deviation: ±1%

Phase Transition Temperature Accuracy: ±0.1K

Phase Transition Temperature Reproducibility: ±0.02K

Enthalpy Accuracy: ±1%

Phase Transition Temperature Reproducibility: ±0.02K

Enthalpy Accuracy: ±1%

Enthalpy Measurement Precision: ±0.25%

Baseline Stability: 200μW

Baseline Reproducibility: ±15μW

Heat Flow Display Resolution: 0.1μW

Heat Flow Peak Noise: 9μW

Indium Peak Height/Half-peak Width: 8mW/K

TAWN Sensitivity: 3

TAWN Resolution: 0.12

Heat Flow Measurement Range: ±750 mW

System Sampling Rate: 50Hz

Gas Atmosphere Control: 3 channels, flow rate adjustable (0~300mL/min)

Power Supply: AC220V/50Hz

Power Consumption: 450W

Dimensions: 505mm × 400mm × 355mm (L×W×H)

Weight: 35kg