New Cosmos - BIE
- Home
- Companies
- New Cosmos - BIE
- Products
- Cosmos - Model TX-KFP - Diffusion Type ...
Cosmos - Model TX-KFP -Diffusion Type Toxic And Combustible Gas Detector
FromNew Cosmos - BIE
TX - KFP - diffusion type detector a diffusion type detector for indoor use. Suitable to detect Hydrogen Fluoride (HF), Hydrogen Sulfide (H2S), Chlorine (Cl2), Silane (SiH4), Boron Trichloride (BCl3), Ammonia (NH3), Arsine (AsH3), Ozone (O3) and many more. The detector can be fitted with an external local indicator. Via the 4-20mA output it can be connected to our controller 8CWA and 16 CWA, V3M or with a PLC type controller.
Most popular related searches
toxic gas
combustible gas detection system
H2S
exhaust monitor
electrochemical monitoring
ethylene oxide
exhaust monitoring
hydrogen cyanide
chlorine dioxide
SO2
- Ideal for safety extract (exhaust) monitoring applications. For example monitoring of gas cabinet extracts
- Low cost solutions
- To be extended with local indicator
- Suitable for almost any type of toxic or combustible gas
- Local indicator
Detectable gases
- 1,1-Dimethylhydrazine C2H8N2
- Acetic Acid CH3COOH
- Acetylene C2H2
- Ammonia NH3
- Arsine AsH3
- Boron Trichloride BCl3
- Boron Trifluoride BF3
- Bromine Br2
- Carbon Monoxide CO
- Chlorine Cl2
- Chlorine Dioxide ClO2
- Chlorine Trifluoride ClF3
- Diborane B2H6
- Dichlorosilane SiH2Cl2
- Diethylamine (C2H5)2NH
- Digermane Ge2H6
- Dimethylamine (CH3)2NH
- Ethyl Alcohol C2H5OH
- Ethylamine C2H5NH2
- Ethylene C2H4
- Ethylene Diamine C2H4(NH2)2
- Ethylene Oxide C2H4O
- Fluorine F2
- Formaldehyde HCHO
- Germanium tetrahydride GeH4
- Hydrazine N2H4
- Hydrogen H2
- Hydrogen Bromide HBr
- Hydrogen Chloride HCl
- Hydrogen Cyanide HCN
- Hydrogen Fluoride HF
- Hydrogen Selenide H2Se
- Hydrogen Sulfide H2S
- Iso Propyl Alcohol C3H8O
- Methyl Alcohol CH3OH
- Methylamine (CH3)NH2
- Nitric Acid HNO3
- Nitric Oxide NO
- Nitrogen Dioxide NO2
- Ozone O3
- Phosgene COCl2
- Phosphine PH3
- Phosphorus Oxichloride POCl3
- Propylene C3H6
- Propylene Oxide C3H6O
- Silane SiH4
- Sulfur Dioxide SO2
- Tetrachlorosilane SiCl4
- Tetrafluorsilane SiF4
- Tetrakis dimethylamido titanium C8H24N4Ti
- Trimethyl Silane (CH3)3SiH
- Trimethylamine (CH3)3N
- Trimetoxy Silane (CH3O)3SiH
- Tungsten Hexafluoride WF6
- Detector model TX-KFP
- Sensor type GS-[ ]DP/ ELP/ EKP
- Detection principle Electrochemical
- Monitoring configuration Continuous, single point, diffusion.
- Detectable gases Please refer to the Toxic Gas (TG) table.
- Accuracy +/- 5% 1)
- Output signal 4-20 mA, 2 wire screened.
- Indicator Optional (digital / analog).
- Operating temp. 0 °C - 40 °C.
- Operating humidity 5 % - 95% (non-condensing).
- Installation Indoor.
- Mounting extract, wall or ceiling.
- Flange connection KF-40.
- Power requirements 24 Vdc.
- Power consumption Max. 0.7 Watt.
- Dimensions Approx Ø 69 x 131 mm.
- Weight 0.5 KG.