Endress+Hauser Group Services AG
  1. Companies
  2. Endress+Hauser Group Services AG
  3. Products
  4. Memosens - Model CCS120D - Digital ...

MemosensModel CCS120D -Digital Total Chlorine Sensor

SHARE

Memosens disinfection sensor for wastewater and process water. Total chlorine is the mixture of free and bound chlorine components and thus a good indicator of residual disinfectants in discharge water. CCS120D provides reliable monitoring of total chlorine limits in the outlet. It reduces your maintenance effort due to easy replacement of electrolyte and membrane cap. Thanks to Memosens digital technology, CCS120D combines maximum process and data integrity. It resists corrosion and moisture, enables lab calibration, and facilitates predictive maintenance.

Most popular related searches
  • Easy handling thanks to Memosens digital technology

  • Enables predictive maintenance due to storage of sensor and process-specific data

  • Low maintenance thanks to fast exchange of membrane cap and electrolyte

  • Flexible installation in CYA112 immersion assembly or CCA250 flow assembly

  • Easy combination with other relevant parameters of liquid analysis thanks to connection to the Liquiline multichannel transmitter

Memosens CCS120D measures total chlorine in:

  • Wastewater treatment plants

    - Disinfection monitoring and control in wastewater outlet

    - Reuse of outlet water

  • Utilities of all industries

    - All disinfection measuring points

  • Measuring principle

    Total Chlorine

  • Application

    Wastewater - optimization of the disinfection process and quality control of outlet water for reuse

    Process water - monitoring, control and optimization of disinfection processes

  • Characteristic

    Amperometric measurement of total chlorine

  • Measurement range

    0.1 to 10 mg/l total chlorine

  • Measuring method

    Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines)

    - all components are reduced at the working electrode
    - almost pH independent

  • Design

    - Closed, membrane covered measuring cell

  • Material

    Sensor shaft: PVC
    Membrane: PTE
    Membrane cap: PPE

  • Dimension

    Diameter: 25 mm (0.98 in)
    Length: 148 mm (5.83 in)

  • Process temperature

    5 to 45 °C

  • Process pressure

    1 to 4 bar (14.5 to 58 psi)

  • Temperature sensor

    10k NTC integrated (Memosens)

  • Connection

    Inductive, digital connection head with Memosens