InsiteModel 10 -Dissolved Oxygen Analyzer

SHARE

TheModel 10 Sensoris our standard sensor mount. This model features all of the above with a PVC 1-1/2" NPT male mounting thread.

Most popular related searches
  • Ouroptical fluorescent technologyprovides increased dependability, no sensor caps, no routine calibration and no need for flow, because there is no oxygen consumption.
  • Thesolid state electronicsmeans no membranes, no fill solutions, and reliable digital communications up to 2000ft.
  • Ourside mount elementincreases impact protection and facilitates the integrated jet clean.

Our continuous DO sensors come standard with tool free ¼" O.D. tubing connectors for the integrated jet clean and 33ft (10m) of sensor communications cable. Additional cable length is available upon request.

  • Measuring Range: 0 to 25 ppm
  • Accuracy: 1% of the reading or .05 ppm, whichever is greater
  • Repeatability: 0.01 ppm
  • Response Time: 95% in under 60 seconds
  • Resolution: 0.01 ppm below 4.00, 0.1 ppm above 4.0
  • Drift: less than 1% per year
  • Temp. Range: 0°C to 60°C
  • 1-½" MNPT mounting thread
  • 33ft (10m) sensor cable
  • ¼" O.D. tube connection for jet cleaning