Endress+Hauser Group Services AG
  1. Companies
  2. Endress+Hauser Group Services AG
  3. Products
  4. Easytemp - Model TMR35 - Hygienic ...

EasytempModel TMR35 -Hygienic Compact Thermometer

SHARE

Compact, fast and precise for the measurement of process temperatures in hygienic applications. With cost efficiency, optimal use of space, reliable operation, easy commissioning and hygienic design the TMR35 fulfills all the requirements in the Food & Beverage as well as in the Life Science industries. A variety of hygienic process connections leads to a high flexibility.

Most popular related searches
  • Small, compact design made entirely of stainless steel

  • Extremely short response times

  • Highly accurate even with short insertion lengths

  • 4-wire, Pt100 or PC-programmable transmitter with 4 to 20 mA output

  • Configuration and visualization with ReadWin® 2000 PC operating software, which is free of charge

  • Breakdown information in event of sensor break or sensor short-circuit, adjustable as per NAMUR NE43

  • Hygienic compatible design with 3-A marking and EHEDG certification; Marine approval

The Easytemp TMR35 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR35 with process connections for hygienic applications.

  • Measuring Principle: Resistance Temperature Detector
  • Characteristic / Application: metric style compact temperature probe fast response time hygienic design hygienic process connection with or without neck
  • Thermowell / protection tube: without (not intended to be used with thermowell) to be used with thermowell incl. T-/ellbow thermowell
  • Insert / probe: pipe version, isolated wires, not flexible
  • Outer diameter protection tube:
    • 3,0 mm (0,12``)
    • 6,0 mm (0,24``)
  • Max. immersion length on request: up to 600,00 mm (23,62``)
  • Material protection tube/ thermowell: 1.4404 (316L) 
  • Process connection:
    • hygienic:
    • conical sealing system G1/2" (metal)
    • clamp connections acc. to ISO 2852 / DIN 32676
    • screwed pipe joint acc. to DIN 11851
    • Varivent
  • Tip shape: straight
  • Surface roughness Ra:
    • 0,4 μm (16 μin.)
    • 0,8 μm (32 μin.)
  • Operating temperature range: PT 100: -50 °C ...200 °C (-58 °F ...392 °F)
  • Max. process pressure (static): at 20 °C: 100 bar (1.450 psi)
  • Accuracy: class A acc. to IEC 60751
  • Response time:
    • t50 = 1 s
    • t90 = 2 s
  • Integration head transmitter: no (4…20mA Signal)
  • Certification:
    • 3A
    • German Lloyd (GL) - marine approval
    • UL 3111-1
    • EAC