NADA Scientific
- Home
- Companies
- NADA Scientific
- Products
- NADA Scientific - Model N600-HZ-7000 - ...
NADA Scientific - Model N600-HZ-7000 -Electrochemical Measurement System
FromNADA Scientific
HZ-7000 is a compact and high performance potentiostat / galvanostat which is equipped with a LCD monitor and includes data memory function. HZ-7000 can perform electrochemical measurements of varieties. HZ-7000 is not only remote-controlled by PC via Ethernet but also capable of basic measurement in stand-alone mode. HZ-7000 offers to various measurement techniques. So it can be used widely, from basic research to applied research.
Most popular related searches
electrochemistry measurement
potentiostat galvanostat
potentiostat/galvanostat
electrochemistry
potentiostat
electrochemical system
galvanostat
weight indicator
scaling control
- HAG1232m: remote-control only
- HAG1232mP: remote-control / stand-alone
- Basic measurement can be performed in stand-alone mode.
- (OCP, LSV, CV, CA, CP, NPV, DPV, IR, SCV, OSWV, ZRA, CDC, etc.)
- Saving the data and measurement condition to USB memory.
- And loading the measurement condition from USB memory.
- The potential of RE/CE and CE/WE is measured simultaneously.
- Minimum current range: 30nA; capable of low current control and measurement
- Arbitrary waveform control up to 99steps.
- Function can be extended by adding option board. (bi-potentiostat, EIS, QCM, etc.)
- Booster option (30V, 3A or 12V, 30A)
- Maximum output voltage: ±12V
- Maximum current: ±300mA
- Potential control range: ±10V (±10V, -5V~+15V, 0V~+20V: with potential shift function) (*1)
- Potential control resolution: 66µV(2Vrange)
- Current control resolution: 0.004% of Full Scale Range
- Potential control accuracy: ±0.05% of setting ±1mV
- Current control accuracy: ±0.2% of Full Scale Range
- Response speed: < 2µ sec
- Potential ranges: 2V, 10V, AUTO (±10V, -5V~+15V, 0V~+20V: with potential shift function) (*1)
- Potential measurement accuracy: ±0.05% of reading ±1 mV
- Potential measurement resolution: 0.003% of Full Scale Range, Minimum 66µV(2Vrange)
- Current ranges: 30nA~300mA(8ranges), AUTO
- Current measurement accuracy: ±0.2 % of Full Scale Range
- Current measurement resolution: 0.004% of Full Scale Range, Minimum 1.1pA (30nA range)
- Input impedance: > 1TΩ
- Input bias current: < 10pA
- Data sampling interval: 10µs ~1800s (There are some limitation depending on method)
- Size: 26cm x 16.5cm x 34cm (L x W x H)
- Net Weight: 5.8 kg
- Gross Weight: 10 kg