Graetz Strahlungsmeßtechnik GmbH
  1. Companies
  2. Graetz Strahlungsmeßtechnik GmbH
  3. Products
  4. Graetz - Model GPD150G - Electronic ...

GraetzModel GPD150G -Electronic Personal Dosemeter

SHARE

The GRAETZ GDP150G is a compact, robust and battery operated electronic personal dosemeter. The so-called alarm dosemeter is equipped with a dose and dose rate warning function at a measurand of Hp(10). The GRAETZ GDP150G is particularly convincing in the case of fire brigades and other forces of civil defense due to its high reliability and ease of use. Operational forces are offered the possibility of permanent self-monitoring.

Most popular related searches
  • Compact design, robust and splash-proof (IP54)
  • An integrated clip makes it easy to attach to clothing
  • Optical and acoustic warning when the set warning thresholds (dose and dose rate) are exceeded.
  • High reliability due to constant self-monitoring
  • Small, handy housing, well decontaminable
  • Dosemeter for measuring gamma and X-ray radiation for the measurand Hp(10) (deep personal dose)
  • Detector: Energy-compensated Geiger-Müller counter tube
  • Switchable acoustic single pulse detection
  • Menu-driven operator guidance
  • Storage of the dose value and the set parameters even when the battery is changed
  • Four factory preset dose warning thresholds
  • Factory preset dose rate warning threshold
  • Visual and audible warning
  • High reliability due to constant self-monitoring
  • Small, handy housing, well decontaminable, protection class IP54
  • Operating time with one set of batteries in ambient radiation approx. 1 month in 24 h operation and 3 months in 8 h operation
  • Audible battery warning
  • Mounting clip and device bag included
  • Measuring range: 1 μSv – 10 Sv
  • Measured variable: Hp (10) (deep personal dose)
  • Radiation type: Gamma and X-ray radiation
  • Energy sector: 55 keV – 1.3 MeV

Equipment variants for use by firefighters and in disaster control additionally with:

  • Display of the remaining residence time until the dose warning is triggered in high dose rate fields.
  • When the device is switched on, the dose warning threshold 15 mSv is always activated
  • GPD150GF-V: Additional vibration alarm when dose and dose rate warning thresholds are reached.