EMAG-SERWISModel MM-2PW -Methanometer for Continuous Methane Monitoring

SHARE

The MM-2PW methanometer is a device specifically engineered for the uninterrupted monitoring of methane concentrations ranging from 0 to 100% CH4. It is predominantly utilized in the mining and gas industries, where tracking methane levels is of utmost importance for maintaining safety. The MM-2PW model is optimized for use in mining environments, while the MM-2PW/A variant addresses pipeline applications. Its design features enable continuous measurement and display of methane concentration data, alongside real-time output status, augmented by telemetry line communication. The methanometer is equipped with alarm systems to indicate when methane levels surpass predetermined safety thresholds. Designed for integration with two-state input and output configurations, the device offers extensive self-diagnostic capabilities to quickly detect and report operational anomalies. Certified for explosive atmospheres, it is approved for both subterranean mining operations and surface areas prone to gas or dust explosions, ensuring top-tier safety standards.

Most popular related searches

A methanometer is an essential device for measuring methane concentration in the air, particularly in the gas and mining industries, where monitoring methane levels is vital for safety. Methanometers are equipped with detectors that allow for precise measurement of even small amounts of methane, enabling quick responses in potentially hazardous situations.

The MM-2PW methanometer is designed for continuous methane concentration monitoring within the range of 0-100% CH4. It is tailored for measurement of methane concentration:

  • In mining atmospheres (MM-2PW model)
  • In pipelines (MM-2PW/A model)
  • Continuous measurement of methane concentration in the atmosphere or pipeline
  • Display of measurement results and output status, with communication to the surface station via a telemetry line
  • Alarm signaling for exceeding set threshold levels
  • Support for two-state input and output systems
  • Self-diagnostics of the methanometer and display of emergency statuses
  • Power Supply: 60 V, 40 mA DC from the telemetry central or from the intrinsic safety power supply.
  • Minimum Power Supply Parameters: 30 V, 40 mA DC.
  • Battery Autonomy: Minimum 8 hours.
  • Maximum Cable Length: 30 m for CKM/W connecting the methanometer to the measurement head.
  • Measurement Type: Continuous in the range of 0-100% CH4.
  • Precise Measurement: Vital for safety in mines and industrial process management.
  • Display of Measurement Results: A clear display that shows the current methane concentration.
  • Display of Output Status: Information about the status of outputs like alarm indicators or relays allows operators to monitor and respond to environmental changes.
  • Telemetry Communication: Communication with the surface station via a telemetry line allows for remote monitoring and control, crucial for mining environments and extensive pipelines.
  • Alarm Threshold Exceedance Signaling: Alerts operators immediately when set alarm thresholds are exceeded, enabling quick reactions to potentially dangerous situations.
  • Support for Two-State Input and Output Systems: Integration with various monitoring and control systems is facilitated.
  • Self-Diagnostics: Continuous monitoring of the device’s status and detection of possible faults or issues in real-time.
  • Emergency Status Display: Provides operators with information on emergency statuses such as measurement errors, communication disruptions, or power issues.