WB Johnson Instruments
WB Johnson - Model ERK-506 -Emergency Response Kit with Radiation Detection
The ERK-506 Emergency Response Kit is designed for accurate and efficient measurement of radiation, specifically targeting threats from alpha, beta, and gamma contamination fields. At its core is the DSM-506 Survey/Scaler meter, capable of measuring radiation levels up to 2000mR/hr with robust precision through features like dual calibrations, selectable from the front panel. This kit integrates an energy-compensated GM detector, an HP-265 GM pancake, and an MRSP-1 near tissue-equivalent scintillator, enhancing its ability to perform low-level contamination assessments. The automatic ranging and diagnostic capabilities underscore its user-friendliness. All equipment pieces are housed in a durable carrying case, ensuring both their safety and ease of transport, catering to on-the-go emergency professionals.Most popular related searches
emergency response
gamma contamination
contaminant assessment
contamination monitoring
survey meter
contamination assessment
gamma radiation
radiation detection system
radiation detection
level monitoring
The DSM-506 kit utilizes the DSM-506 Survey/Scaler meter to measure most alpha, beta, and gamma radiation & contamination fields from background to 2000mR/hr. Internal energy compensated GM detector, HP-265 GM pancake, and the MRSP-1 near tissue-equivalent scintillator are connected to the meter and can have dual (dose or CPM calibrations) that are switch selectable from the front panel. The timed count scaler function makes low-level contamination measurements more accurate once the operator selects the desired probe. Automatic ranging and diagnostics make the system extremely user-friendly. All components of the system are contained in a durable carrying case for easy storage and portability.
- Large digital display
- Auto ranging units
- Dual mode capacity for
- Dose rate & count rate
- 3 detectors – internal gm
- Hp-265 and MRSP-1
- Dose/Counts Switch: Change Dose Rate to Count Rate by Toggling an External Switch
- Display: LCD 4-Digit x .75″ LCD w/LED Backlight
- Internal Detector: Energy Compensated GM Tube
- Energy Range: 60 keV – 3 MeV
- Internal Detector Dose Range: 50 μR/hr – 2000 mR/hr or equivalent Sv/hr
- External Probes: HP-265 and MRSP-1
- CPM Range: 0-999.9 Kcpm or Kcps
- Probe Linearization: Internal adjust for calibration constant and dead time
- Scaler Ranges: 0-999.9 Kcounts
- Scaler Count Time Ranges: 10-2550 Seconds (10 second increments)
- Alarms: 5-95% of Range
- Diagnostics: Low Battery, Over-range – Audible & Visual Alarms
- Range Adjustment: Auto-Ranging All Scales
- Electrical Non-Linearity: < 5% Full Scale
- Response Time: Fast – 10-2550 Seconds (adjustable) / Slow 10-250 seconds (adjustable)
- Drift: < 5%
- Environmental: -20°F[-28°C] to 140°F[60°C]| 5-95% RH IPX4 Housing
- High Voltage Adjustable: 400-1250 VDC | Regulation +-1%
- Battery: 6 – “AA” Alkaline (nominal 200hrs Operation)
- Dimensions: 5.25″(14cm) H X 4″ (10cm) W x 7″(18cm) L
- Weight: 2.5 lbs. (1.2 Kilos)