WB Johnson Instruments

WB JohnsonModel ERK-506 -Emergency Response Kit with Radiation Detection

SHARE
The ERK-506 Emergency Response Kit is designed for accurate and efficient measurement of radiation, specifically targeting threats from alpha, beta, and gamma contamination fields. At its core is the DSM-506 Survey/Scaler meter, capable of measuring radiation levels up to 2000mR/hr with robust precision through features like dual calibrations, selectable from the front panel. This kit integrates an energy-compensated GM detector, an HP-265 GM pancake, and an MRSP-1 near tissue-equivalent scintillator, enhancing its ability to perform low-level contamination assessments. The automatic ranging and diagnostic capabilities underscore its user-friendliness. All equipment pieces are housed in a durable carrying case, ensuring both their safety and ease of transport, catering to on-the-go emergency professionals.
Most popular related searches

The DSM-506 kit utilizes the DSM-506 Survey/Scaler meter to measure most alpha, beta, and gamma radiation & contamination fields from background to 2000mR/hr. Internal energy compensated GM detector, HP-265 GM pancake, and the MRSP-1 near tissue-equivalent scintillator are connected to the meter and can have dual (dose or CPM calibrations) that are switch selectable from the front panel. The timed count scaler function makes low-level contamination measurements more accurate once the operator selects the desired probe. Automatic ranging and diagnostics make the system extremely user-friendly. All components of the system are contained in a durable carrying case for easy storage and portability.

  • Large digital display
  • Auto ranging units
  • Dual mode capacity for
  • Dose rate & count rate
  • 3 detectors – internal gm
  • Hp-265 and MRSP-1
  • Dose/Counts Switch: Change Dose Rate to Count Rate by Toggling an External Switch
  • Display: LCD 4-Digit x .75″ LCD w/LED Backlight
  • Internal Detector: Energy Compensated GM Tube
  • Energy Range: 60 keV – 3 MeV
  • Internal Detector Dose Range: 50 μR/hr – 2000 mR/hr or equivalent Sv/hr
  • External Probes: HP-265 and MRSP-1
  • CPM Range: 0-999.9 Kcpm or Kcps
  • Probe Linearization: Internal adjust for calibration constant and dead time
  • Scaler Ranges: 0-999.9 Kcounts
  • Scaler Count Time Ranges: 10-2550 Seconds (10 second increments)
  • Alarms: 5-95% of Range
  • Diagnostics: Low Battery, Over-range – Audible & Visual Alarms
  • Range Adjustment: Auto-Ranging All Scales
  • Electrical Non-Linearity: < 5% Full Scale
  • Response Time: Fast – 10-2550 Seconds (adjustable) / Slow 10-250 seconds (adjustable)
  • Drift: < 5%
  • Environmental: -20°F[-28°C] to 140°F[60°C]| 5-95% RH IPX4 Housing
  • High Voltage Adjustable: 400-1250 VDC | Regulation +-1%
  • Battery: 6 – “AA” Alkaline (nominal 200hrs Operation)
  • Dimensions: 5.25″(14cm) H X 4″ (10cm) W x 7″(18cm) L
  • Weight: 2.5 lbs. (1.2 Kilos)