Endee Engineers Pvt. Ltd.
  1. Companies
  2. Endee Engineers Pvt. Ltd.
  3. Products
  4. Endee - Model 8420 - Multi Channel Gas ...

EndeeModel 8420 -Multi Channel Gas Controller Controller

SHARE

The ENDEE 8420 Universal Receiver Controller is a microcontroller-based gas detection control system for continuous 24/7 monitoring of atmospheric hazards. Designed for industrial applications, it offers a modular design, supporting up to 8 channels in a 19″ rack mount. Its intuitive interface, software-adjustable alarm set points, and compatibility with remote gas transmitters make it ideal for safe and efficient operations.

Most popular related searches
  • Modular design with 2 to 8 channel capacity
  • Discrete 4-20 mA analog outputs for integration
  • RS 485 communication option for remote monitoring
  • Compatible with PLCs, SCADA, and DCS systems
  • Software-adjustable alarm set points in 1 PPM/% increments
  • Three-digit indicator for real-time gas concentration readings
  • Alarm disable and silence functions for user convenience
  • Industrial gas detection and monitoring systems
  • Atmospheric hazard detection in manufacturing environments
  • Integration with PLC, SCADA, and DCS systems
  • 24/7 safety monitoring in hazardous environments
  • Compliance and safety reporting through remote monitoring
  • Input: 4-20 mAcurrent Loops
  • Displays: Red LED – 3 digit 7 segment for gas level.
  • Indications LED: Low alarm. High alarm, Fault
  • Alarm Reset: Is accomplished via an Integral or remote switch
  • Electrical Classifications: NEMA 1 panel mount
  • Capacity: Up to 8 single channel control modules
  • Power Input: 220 VAC Standard / 24 VDC Optional
  • Power Consumption: <5 watts per channel (includes gas sensor transmitter and control module)
  • Output: Linear analog 4-20 mA DC, 24 volt DC, Serial Rs-485/ 232, Discrete relays for fault, low and high alarm
  • Operating Temperature: -10Cto55C
  • Humidity Range: 0 to 95% RH, non-condensing
  • Dimension: 3U 19″ Rack
  • Warranty: One year except batteries, Sensor one year in air.

The above Parameter and Ranges are only indicative. Endee will build up and supply the analyser with Parameters, range and features to any Practical Configuration.

Note : Specifications and Features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. Due to endee’s commitment to research, design and product improvement, specifications are subject to change without notice