ENVEA

ENVEAModel MIR 9000P -Portable stack testing multi-gas analyzer NDIR-GFC

FromENVEA
SHARE

The ENVEA MIR 9000P belongs to the new generation of ENVEA gas monitors, showcasing eco-design, IoT and on board intelligence. It measures simultaneously 8 gases – NOx, SO2, CO, CO2, CH4, N2O, O2 and residual H2O – and uses the non-dispersive infrared method (NDIR-GFC) with gas filter correlation. O2 is measured by a built-in SRM paramagnetic sensor. The analyzer has been designed to meet the specific needs of on-site regulatory measurement providing superior mobility, robustness, accuracy and compliance. All this makes up for a unique gas emission monitor offering high productivity and low operational cost.

Most popular related searches

INCREASED MOBILITY & PRODUCTIVITY

  • Lightweight (15 kg/33 lbs), compact and extra resistant transport case
  • Standby mode guarantees the instrument is operational at any time

ROBUST DESIGN

  • Extended operating temperature ranges
  • High protection (IP 44) against water splashing from any direction

STAY CONNECTED & GET ON WITH OTHER TASKS

  • Remote access to full operation thanks to ENVEA Connect™ App and proprietary WiFi
  • Smartphone alerts and notifications

ONE CLICK OPERATIONS

  • Integrated user guidance and shortcuts to key functions: calibrations, span check, zero, etc.
  • Secured user management

QUICK INSTALLATION

  • Warm-up time: 30 min maximum
  • Robust gas connectors
  • Self-adaptive measuring scales
  • Compatible with most sampling systems on the market

PREPARE REPORT ELEMENTS WHILE ON SITE

  • Direct access to real-time and stored data ; time frame selection to generate graphs
  • All data can be saved on USB memory stick

MAXIMIZED UPTIME OF THE ANALYZER

  • Turn-up lid designed for quick access to operational modules and easy maintenance
  • Modular design and Plug & Play parts (O2 probe, NOx converter, protection filter, etc.)
  • Regulatory and periodic stack emission monitoring for industrial combustion sites, boilers, etc.

Measuring Ranges

  • NOx as NO
  • (after NOx converter): 0-70/2000/3300 mg/Nm3
  • 0-50/1500/2500 ppm
  • NOx as NO2
  • (after NOx converter): 0-110/3000/5000 mg/Nm3
  • SO2:
    • 0-141/1410/8500 mg/ Nm3
    • 0-50/500/3000 ppm
  • CO:
    • 0-60/3000/8000 mg/Nm3
    • 0-50/2400/6500 ppm
  • CO2: 0-20/30% vol.
  • N2O:
    • 0-1000 mg/Nm3
    • 0-500 ppm
  • CH4:
    • 0-70/700 mg/Nm3
    • 0-100/1000 ppm (higher range upon request)
  • O2:
    • 0-10/25% vol.
    • measured by a built-in paramagnetic sensor
  • Residual H2O: 0-2% vol.

Technical Specifications

  • QAL1 to EN 15267-4 certified: Pending
  • US EPA compliance: YES
  • Sampling technology: Cold/Dry Extraction (gas cooler)
  • Sample transfert: non heated polytube / heated sampling line
  • back flush function: N/A
  • span injection: YES
  • Built-In O2 option: YES
  • Serial link communication:
    • 3 x USB ports type A: 2.0 (compatible 3.0)
    • 1 x RJ45 (MODBUS TCP, MODBUS RTU (dongle) UDP Protocol)
  • Other Communication: WiFi (via USB)
  • Analogue OUTPUTS: Option: 8 analog outputs (0-1 V, 0-10 V, 0-20 mA, ou 4-20 mA)
  • Analogue INPUTS: Dynamic 250 mV or 10V (only one input can be used at once)
  • Dimensions (mm): 641 x 209 x 393mm (WxDxH)
  • Compliant with EN 15267-4
  • US EPA