Orga BV
Orga - Model FH800EX-3 -Explosion Proof Foghorn
FromOrga BV
Explosion proof foghorn, designed to provide 2 nautical miles omni-directional coverage. For man-made offshore structures and in line with IALA regulatory requirements. Can be supplied as a combined main/secondary (2/½ Nm) foghorn together with duplicated controls in the Navaid Central Control Panel (NCCP).
Most popular related searches
climate change standard
explosion hazard
hazard warning
climate change
gas hazard
explosive gas
hazardous gas
integrity monitoring
Standards/Certification
- Complies with IALA regulation; O-139 The marking of man-made offshore structures – September 2020; chapter 2, paragraph 2.1.2 – fog signal
- Complies with IALA guideline; G1162; The marking of man-made offshore structures – December 2021, chapter 2.1.2 – hazard warning signals (HWS)
- Complies with UK Department of Energy and Climate Change; Standard marking schedule for offshore installations – April 2011; chapter 4 – secondary fog signal
- Complies with Mining regulations of the Netherlands – January 2022, Article 5.2 – Fogsignal
- Complies with US Coast Guard; 33 C.F.R. Part 67 – Aids to navigation on artificial islands and fixed structures
- Cenelec EN 60079-0, EN 60079-1 and EN 60079-7
- KEMA 02ATEX2269 (foghorn); ATEX II 2G Ex eb llC T6 Gb
- KEMA 02ATEX2103 X (junction box); ATEX II 2G Ex db llB T6 Gb
- IEC 60079-0, IEC 60079-1 and IEC 60079-7
- IECEx DEK 11.0105 (foghorn); Ex eb IIC T6 Gb;
- IECEx KEM 09.0089X (junction box); Ex db IIB T6 Gb
- ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1 and ABNT NBR IEC 60079-7
- Inmetro NCC 13.1778 (foghorn) (optional)
- Inmetro NCC 22.0085 X (junction box) (optional)
Electrical characteristics
- Operating voltage: 190Vac; 860Hz from Navaid Central Control Panel (NCCP)
- Power consumption: 80 W peak max (Digital modular NCCP)
- Connection details: max. 4 mm²; one M25x1.5 cable gland entry
- Earth connection: internal 4 mm² and external M6
Physical characteristics
- Dimensions (L x W x H):
678 x 464 x 1900 mm - Weight: 175 kg; lifting eye suitable for lifting 700 kg
- Degree of protection: IP66
- Operating temperature range:
–55°C to +55°C
System design, control and monitoring
- Control and monitoring via separate control panel (see separate product information sheet)
Performance characteristics
- Morse code ‘U’ every 30 seconds from Navaid Central Control Panel (NCCP)
- Alternative codes available; e.g. USCG: 2 seconds blast every 20 seconds
- Alternative codes available; USCG 2 sec blast every 20 seconds (2 sec sound, 18 sec silence)
- Usual range main foghorn: 2.0NM (134dB(A) at 1 m)
- Horizontal sound output: 360°
- Reliable marine foghorn, low cost of ownership
- Suitable for Zone 1 and Zone 2 areas with gas explosion hazard; ATEX & IECEx certified
- Operating voltage and code control provided from Navaid Central Control Panel (NCCP)
- Monitoring system integrated in Navaid Central Control Panel (NCCP)
- Offshore coated seawater resistant light alloy body
- Can be supplied as a main/secondary (2/½Nm) foghorn together with duplicated controls in the Navaid Central Control Panel (NCCP)