Fire Investigation Kit - For Fire and Arson Investigation

SHARE

The ION Science Fire Investigation Kit with Tiger or Tiger LT photoionisation detector (PID) has been specifically designed to provide you with all the tools for a convenient, easy-to-use solution for the detection of volatile organic compounds (VOCs) within Fire and Arson Investigation applications. In suspected arson cases, it is part of the investigation to prove that there is no other cause of the fire. The Fire Investigation Kit can be used to detect hydrocarbon compounds such as those found in petrol, alkanes, and cycloalkanes. Fire investigators including the police, consultants and private investigators acting on behalf of insurance companies, will search for every type of fire accelerant such as grill lighters, lighter fuel, liquid glue and cleaning agents.

Most popular related searches

The Fire Investigation Kit includes an AA battery back for emergency power source during long fire and arson investigations!

Ultimate Performance
  • Detects VOCs from 0 up to 20,000 ppm
  • Minimum sensitivity 0.001 ppm (1 ppb)
  • Detects over 480 VOCs and toxic compounds
  • Fast 2-second response time and quick clear down
Ultimate Safety
  • Includes an AA TIGER battery pack for emergency power source during long shifts
  • Integrated flashlight for dark or dimly lit areas
  • Flexi-probe for versatile, practical detection of VOCs in hard-to-reach places
  • Specification: Value
  • Minimum Resolution*: 1 ppb or 0.001 mg/m3
  • Maximum reading**: 20,000 ppm or 20,000 mg/m3
  • Response time: T90 < 2 seconds
  • Accuracy***:
  • ± 5 % display reading ± one digit
  • Intrinsically safe approvals:
    • II1GExiaIICT4Ga
    • Tamb = – 15 °C ≤Ta ≤ +45 °C (with lithium ion battery pack)
    • Tamb = – 15 °C ≤Ta ≤ +45 °C (with alkaline battery pack)
    • ITS09ATEX26890X IECEx ITS 10.0036X
    • 3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1
    • Class 1 Division 1. Approval for Groups A, B, C & D, T4
  • Battery Life:
    • Li-ion: life up to 24 hours, charge time 6.5 hours
    • Alkaline: 3 x AA, typically 8.5 hours life
  • Lamps:
    • 10.6 eV Krypton PID lamp (standard.)
    • 10.0 eV and 11.7 eV lamps available
  • Data Logging*: 120,000 data log points including date and time stamp
  • Communication: Direct USB 1.1
  • Calibration: 2 and 3 point calibration (via calibration kit accessory)
  • Alarm:
    • Flashing LEDs Amber (low alarm) Red (high alarm)
    • Sounder 95 dBA at 300 mm (12″)
    • Vibration on alarm
    • Pre-programmed TWA and STEL*
  • Flow Rate: ≥ 220 ml/min (with blocked flow alarm)
  • Temperature:
    • Operating: -20 to 60 °C, -4 to 140 °F (non intrinsically safe)
    • Humidity: 0 – 99 % RH (non condensing)
  • Protection:
    • Designed to IP65 (heavy rain)
    • EMC tested to EN61326- 1:2006, EN50270:2006 & CFR 47:2008 Class A
  • Weight & Dimensions:
    • Instrument with probe: Width: 340 x Height: 90 x Depth: 60 mm (13.4 x 3.6 x 2.4”)
    • Standard case: 367 x 89 x 90 mm (14.45 x 3.54 x 2.36”)
    • Instrument weight: 0.72 kg (1.56lb)