ION Science Ltd.
  1. Companies
  2. ION Science Ltd.
  3. Products
  4. Falco Pumped - Fixed VOC Gas Monitor

Falco PumpedFixed VOC Gas Monitor

SHARE

The Falco Pumped is a fixed VOC gas monitor that eliminates false readings found with other competing technology and continuously detection Volatile Organic Compounds (VOCs) in hazardous areas. The Falco pumped, fixed VOC gas monitor uses a sample line to draw samples and is ideal for use in difficult locations such as underground or in confined spaces.

Most popular related searches

Falco, fixed VOC gas monitor has an externally located Intrinsically Safe sensor for quick and easy servicing without the need for a hot work permit. Dual certification allows Falco to be serviced and calibrated in a hazardous environment without having to remove power!

The standard Falco, fixed gas monitor, both pumped and diffused models are supplied with a 10.6 eV lamp allowing the instrument to detect a wide range of VOC gases. The Falco VOC detector has 4 detection ranges available, these ranges include 0 – 10 ppm, 0 – 50 ppm, 0 – 1000 ppm and 0 – 3000 ppm.

The Falco TAC, both Pumped TAC and Diffused TAC models, utilise a 10.0 eV lamp to detect Total Aromatic Compounds (TACs) which help focus on benzene. The Falco TAC is available with a detection range of 0 – 50 ppm.

Ultimate Performance
  • The only VOC detector specifically designed for extreme weather
  • Typhoon technology stops condensation forming with the PID
  • Cutting-edge sensor performance minimises drift & downtime
Ultimate Safety
  • Eliminates false readings found with competing PID technology
  • Multi-coloured status display can be seen from 20 metres in sunlight
  • Fitted with long-life lamp for one year continuous use
  • Ex d approved
Ultimate Flexibility
  • Pumped and diffused models available
  • Pumped unit idea for difficult to access locations
  • Four detection ranges available
  • Selectable response factor for varying VOC selection

Specification: Value

  • Sensor: Photoionisation detector
  • Detection ranges and sensitivity with 10.6 eV lamp fitted* :
    • 10.0 ppm, 0.001 ppm
    • 50.0 ppm, 0.01 ppm
    • 1000 ppm, 0.1 ppm
    • 3000 ppm, 1 ppm
  • Detection ranges and sensitivity with 10.0 eV lamp fitted*: 50.0 ppm, 0.01 ppm
  • Response Time (T90): Pumped models: <10 seconds**
  • Accuracy: ± 5 % or ± 1 digit
  • User Interface:
    • OLED high contrast white on black: 128 x 64 pixels
    • Screen size: 35 mm (w) x 17.5 mm (h)
    • 5 magnetic switches with LED confirmation (up, down, left, right and enter)
  • Status indicator: Bright visible status indicator: RED, AMBER, GREEN
  • Output:
    • 4 – 20 mA
    • 2 programmable relays
    • RS 485 Modbus
  • Falco diffused environmental specification:
    • Operational Temperature: – 40 to 50 °C 0-100 % RH and condensing humidity
    • Storage temperature: – 40 to 60°C
  • Ingress Protection:
    • Main Unit:IP65
    • Sensor Head: IP65
  • Power: Working voltage: 12 to 40 Vdc
  • Typical 2 W, Max 7 watts
  • Mechanical Interface: 2 x cable entry points with 3/4″ NPT threads (left and right)
  • Mounting Points: 2 x M8
  • Weight and Dimensions:
    • 3.3 kg
    • 291 (h) x 191 (w) x 125 (d) mm
  • EMC: EMC Directive 2014/30/EU
  • Certification:
    • II 2G db ib IIC T4 Gb
    • Class 1, Div 1 Groups ABCD T4
    • ISO9001:2015

* All specifications quoted are at calibration point and under the same ambient conditions.
Specifications are based on isobutylene calibration at 20 °C and 1000 mBar.
** When set to continuous measurement