- Home
- Companies
- eralytics GmbH
- Products
- eralytics - Model ERAFLASH S10 - Flash ...
eralytics - Model ERAFLASH S10 -Flash Point Autosampler
The ERAFLASH S10, produced by eralytics, is a sophisticated flash point tester that integrates a 10-position autosampler to deliver efficient, reliable, and safe flash point measurements. Utilizing CCCFP methods such as ASTM D7094, ASTM D6450, and IP620, the ERAFLASH S10 is designed for unattended operations requiring only 1-2 ml of sample. It`s engineered for high-throughput laboratories and requires minimal space. The device employs Peltier Boost Technology® to allow testing across a temperature range of -25 °C to 420 °C. This technology not only enables precise temperature control but also reduces turnaround time by managing the elements through differential heating and cooling cycles. The optional cooling lid serves to maintain stable temperatures for volatile samples, enhancing the accuracy and reliability of results.
Autosampler for Flash Point Testing
ERAFLASH S10 is the first 10-position autosampler for flash point testing. It uses the intrinsically safe methods ASTM D7094 and ASTM D6450. With a low sample volume of 1-2 ml only and the continuously closed sample cups they are ideally suited to built a completely safe autosampler for flash point testing.
This makes ERAFLASH S10 the ideal solution for unattended flash point testing.
When looking at valuable products, especially with small batch sizes, flash point testing using the well-known Pensky Martens principle can consume a significant amount of sample, thus leading to high analytical costs. When performing flash point testing according to ASTM D7094 just 2 ml of the sample are needed. ASTM D6450 reduces this volume even further to 1 ml.
ERAFLASH S10 is therefore a welcome addition to testing labs handling large amounts of costly samples every day. This includes fragrances, paints and varnishes producers.
Similar to eralytics’ single position flash point tester the patented PBT – Peltier Boost Technology™ allows flash point testing below 0°C (32°F) and above 200°C (392°F) with a single instrument. PBT separates the Peltier elements during the heat up at 100°C shielding them from higher temperatures that would normally harm them. During cool down, however, they can be used for active cooling starting at 200°C and thus reduce the turnaround time significantly. PBT also facilitates the same temperature range of -25°C (-13°F) to 420°C (788°F) of our single position flash point tester in an autosampler for flash point testing.
Optional Cooling Lid
Another great benefit is the optional cooling lid for the ERAFLASH S10 ten-position autosampler – which is a unique solution for many reasons: The pre-cooled lid allows easy and time-saving sample preparation. As a consequence the sample cups are pre-cooled as well what means that no complicate cooling prior sample filling is necessary.
The pre-cooled samples need less intensive cooling during sample measuring resulting in shorter turn-around times. As no elevated temperatures are reached and volatile compounds are far less likely to evaporate before measurement is started, more precise and reliable results are reached.
Just four easy steps are required for an unattended safe and fast flash point testing at maximum precision:
- Enter sample IDs and operator name
- Select the measurement standards and add additional parameters (e.g. expected flash point)
- Fill up to 10 sample cups with samples, place the sample cups on the carousel and close the cover plate
- Press the RUN button
During flash point testing the instrument visualizes the measurement procedure on the screen showing the sample and oven temperature as well as pressure gauge displaying the pressure increase after ignition.Additional information about the currently measured sample, as well as finished and still samples to be measured are displayed. After the measurements the flash point temperature is corrected for the atmospheric pressure and rounded to the next 0.5°C. All results will be saved in the corresponding result file.
Available Test Methods
ASTM D6450, ASTM D7094, IP620, SH/T 0768
Pre-Programmed Correlation Methods to...
Pensky Martens Closed Cup: ASTM D93, EN ISO 2719, DIN 51758, IP34, JIS K2265
TAG Closed Cup: ASTM D56
Abel Pensky Closed Cup: ISO 13736, IP170
Small Scale Closed Cup and Flash / No Flash methods: EN ISO 3679, EN ISO 3680, ASTM D3828
Fuel Specifications (ASTM D7094)
ASTM D396, ASTM D975, ASTM D2880, ASTM D3699, ASTM D7467
Speed Tests
Fast screening test programs for unknown samples
Sample Handling
10 position autosampler
PBT - Peltier Boost Technology®
High speed heating & cooling
-25 °C to 420 °C (-13 °F to 788 °F) with a single analyzer
CPT - Contamination Prevention Technology™
Advanced electrode protection and self-cleaning ignition system to minimize cleaning and maintenance
Combustion Graphics™
Display of combustion characteristics for contamination analysis
QC Mode
Built-in quality control mode including on-screen QC charts
Cooling Lid Temperature
5 °C to 30 °C (optional)
QuickCal™
In-situ calibration with eralytics unique calibration cups without the need of dismantling the instrument
Fuel Dilution Program
Automatic fuel dilution measurement for the analysis of used engine oils
Temperature Range
0 °C to 200 °C (32 °F to 390 °F) stand alone
down to -25 °C (-13 °F) with external cooling
up to 420 °C (788 °F) with optional High Temperature Module
Temperature Stability
0.1 °C (0.2 °F)
Unattended Sample Throughput
10 loaded samples within approximately 45 minutes (depending on temperature range)
Sample Volume
1 mL (ASTM D6450), 2 mL (ASTM D7094)
Sample Cups
Nickle plated aluminium, stainless steel cups available upon request
Result Database
Over 100 000 detailed test reports stored in internal memory
Alarm Tracking
All alarm messages are stored in the database together with the result
Display
Industry proven 8.4" color touchscreen
Languages
English, German, French, Spanish, Russian, Chinese
Additional langages available upon request
Interfaces
Built-in PC with Ethernet, USB and RS232 interfaces
Direct LIMS connectivity and output to printer or PC
Optional input by external keyboard, mouse and barcode / QR-code reader
Wifi via external USB dongle
Remote Control
Remote service capability via Ethernet interface
PC Software
ERASOFT RCS - remote control Windows® software for multi-instrument remote control, convenient data transfer andresult analysis
Operating Conditions
Temperature range 10 °C to 40 °C
Humidity up to 90% RH, non-condensing
Power Requirements
Auto-switching 85-264 V AC, 47-63 Hz, max. 150 W (multi-voltage power supply)
Field application: 12 V DC (vehicle battery) adapter available
Dimensions / Weight