MRU Messgerate fur Rauchgase und Umweltschutz GmbH

MRUModel DELTAsmart -Flue Gas Analyser

SHARE
Modern and powerful flue gas analyser for residential and commercial heating installations.
Most popular related searches

Basic-Equipment

  • O2-sensor
  • CO-Sensor, non-H2-compensated (using CO sensor version E)
  • CO-Sensor, H2-compensated (using CO sensor version B)
  • Gas temperature measurement up to 1200°C with K-type thermocouple
  • Combustion air temperature 0 - 100°C with K-type thermocouple
  • Stack / Differential pressure: ± 100 mbar
  • Differential temperature mesurement
  • Ambient air CO tester
  • Gas sampling probe with fixed Ø 8 x 250 mm stainless steel tube
    and 1,5 m triple silicone gas sampling hose
  • Large condensate trap with Teflon coated particulate filter
  • High capacity, Lithium-Ion rechargeable battery
  • Mini-USB interface to PC and SD card slot for large volume data logging
  • Internal data storage for up to 1.000 measurements
  • IRDA printer interface

NO measurement (NOx calculated)

  • 0 ... 1.000 ppm, overload up to 5.000 ppm

Outstanding benefits:

  • Modern technology, high accuracy and performance
  • Colour and backlit touchscreen, intuitive and easy to use
  • Up to 3 electrochemical cells for O2, CO and NO
  • Compatible with new MRU App "MRU4u" *
  • TÜV approved according to EN 50379-1+2 (model B) resp. 50379-3 (model E), ByRgG 309

Measuring range

  • O2: 0 ... 21,0 % Vol-% abs., resolution 0,1 %
  • CO (H2 compensated): 0 ... 4.000 ppm (overload up to 10.000 ppm), resolution 1 ppm
  • NO: 0 ... 1.000 ppm (overload up to 5.000 ppm), resolution 1 ppm
  • Fluegas temperature: -40 ... +1.200 °C, resolution 0,1°C
  • Differential temperature: -40 ... +1.200 °C, resolution 0,1 °C
  • Draught: ± 50 hPa, resolution 0,01 hPa
  • Differential pressure: ± 100 hPa (mbar), resolution 0,01 hPa
  • Combustion air temperature: 0 ... 100 °C, resolution 0,1 °
  • NO(x):

Calculated values

  • Dew point: °C, resolution 0,1 °
  • Heat losses qA: 0 ... 99,9 %, resolution 0,1 %
  • Combustion efficiency: 0 ... 120 %, resolution 0,1 %
  • Excess air: 0 ... 999 %