ZetianModel EM-5 -Flue Gas Analyzer (Hot-Wet)

SHARE

EM-5 Flue Gas Analyzer (hot-wet) is a gas analysis product of multi-return optical path on basis of years of accumulated ultraviolet absorption spectroscopy. Based on Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) and Stoichiometric Algorithm (PLS), the analyzer can measure SO2, NO, NO2, O2, NH3, CO, CO2, Cl2, O3, H2S,HCl, CH3I, CH2O, etc. In addition, our analyzer can configure with self-developed built-in infrared module to measure CO according to customer requirement, which has higher accuracy and reliability, faster response compared to electrochemistry method solves problem of short service life.

Most popular related searches
  • High-temperature tracing without cold ends effectively prevents measurement values from being underestimated due to the dissolution of SO2 and NO2 by condensation water.
  • Using UV differential absorption spectroscopy technology and a long optical path gas cell, the detection limit is as low as 0.1 μmol/mol with high sensitivity.
  • NO and NO2 can be directly measured simultaneously without a converter.
  • Not affected by background components such as H2O, CH4 , CO, NH3 , and dust.
  • Measurement results are not affected by temperature or vibration, ensuring high stability.
  • The pulse xenon lamp has a long service life.
  • The analysis module has no optical moving parts, making it unaffected by vibration.
  • The gas cell is robust and has low maintenance costs.
  • Continuous Emission Monitoring System (CEMS) for power plant flue gas emissions (analyzing SO2, NO, NO2, O2)
  • Desulfurization process monitoring (analyzing SO2, O2)
  • Denitrification process monitoring (analyzing NO, NO2, NH3, O2)
  • Continuous monitoring of flue gas emissions from waste incineration (analyzing SO2, NO, NO2, O2)
  • Minor Cl2 analysis in the PVC process and titanium dioxide production process of chlor-alkali plants (analyzing Cl2)
  • Gas analysis for sulfur recovery processes (analyzing SO2, H2S)
  • Gas analysis for natural gas purification processes (analyzing minor H2S)
  • Principle: SO2 , NO, NO2 : UV-DOAS; O2 : Zirconia
  • Components & ranges: SO2 , NO, NO2 : 0~100mg/m3 (customizable range / dual range); O2 : 0~25%
  • Repeatability: ≤2%
  • Stability: ≤5%
  • Zero drift: Within ±2.5%F.S./7d
  • Span drift: Within ±2.5%F.S./7d
  • Response time (T90): ≤50s
  • Analog signal: DC 4-20mA, 4 outputs, 3 inputs, configurable
  • Digital signal: 13 outputs, 6 inputs, configurable
  • Comm: RS-232/RS-485
  • Sample flow rate: 2L/min
  • Ambient temp: (0~40)?
  • Ambient humidity: ≤85%RH, non-condensing
  • Power supply: AC (220±22)V, (50±1)Hz
  • Power consumption: About 120W