Fox Thermal
Fox - Model FT4X -Thermal Gas Mass Flow Meter
FromFox Thermal
The Fox Thermal Model FT4X, is the newest Thermal Gas Mass Flow Meter offered from Fox Thermal. Its BLM accuracy compliant Data Logger has a 7-year history!
Most popular related searches
gas mass flow metering
gas mass flow meter
mass flow metering
gas mass flow
mass flow meter
thermal mass flow meter
flow meter
gas thermal mass flow meter
NIST traceable calibration
mass flow
- Insertion, Inline & Remote Styles
- DDC-Sensor™ Technology
- Gas-SelectX® & CAL-V™
- Advanced Data Logger for BLM
- Scroll down for more features/benefits!
- Gas Refineries
- Petrochemical Production
- BLM Gas Leases
- Flares & Combustors
- And many more applications...
Common Features for Fox Thermal Model FT4X Flow Meter:
- Measures process gas flow rate/total and temperature
- Insertion probes (for 1.5" - 70" pipes); Inline flow bodies with NPT ends (3/4" - 3" pipes); Inline 150# & 300# Flanged flow bodies (3/4" - 6" pipes)
- Equipped with the 3rd Generation DDC-Sensor™ (Direct Digitally Controlled)
- Gas-SelectX® expanded gas selection menu. Choose from available list of gases/gas mixes to measure flow. NIST-traceable calibration
- Advanced Data Logger with Real Time Clock and 40 24-Hour daily totals
- Settable Contract Time defines Contract Day
- A USB connection is standard (free FT4X View™ Software); Optional HART and Modbus RTU (RS485) communication protocols
- Standard on-board display and configuration panel
- Two standard isolated 4-20mA outputs: Channel 1 configured to indicate flow, fault indication per NAMUR NE43. HART communication option; Channel 2 configured to indicate either flow or temperature
- One isolated open collector output for pulse/alarm
- One switch input to reset total
- Click the Approvals tab for Model FT4X Agency Approval details
- Calibration Validation with the CAL-V™ test
- NIST-traceable calibration
- Wide measurement range
- Flow Accuracy for air: ±1% R ±0.2% FS; Flow accuracy for other gases: ±1.5% R ±0.5% FS
- 24 VDC or optional 100 to 240VAC in local or remote enclosures
CE: Approved
- EMC Directive; 2014/30/EU
- Electrical Equipment for Measurement, Control and Lab Use: EN61326-1:2013
- Low Voltage Directive (LVD): 2014/35/EU
- Product Safety Testing: EN 61010-1: 2010
- Pressure Equipment Directive: 2014/68/EU Article 13
- Weld Testing: EN ISO 15614-1 and EN ISO 9606-1, ASME B31.3
FM (FM17US0061X) and FMc (FM17CA0032X): Approved
- Class I, Division 1, Groups B, C, D;
- Class II, Division 1, Groups E, F, G;
- Class III, Division 1; T6 or T4, Ta = -40°C to 70°C;
- Class I, Zone 1, AEx/Ex db IIB+H2 T6 or T4; Gb Ta = -20°C to 70°C; Type 4X, IP67
ATEX (FM17ATEX0015X): Approved
- II 2 G Ex db IIB+H2 T6 or T4; Gb Ta = -20°C to 70°C; IP67
- II 2 D Ex tb IIIC T85°C or T135°C; Db Ta = -20°C to 70°C; IP67
IECEx (IECEx FMG 17.0008X): Approved
- Ex db IIB+H2 T6 or T4; Gb Ta = -20°C to 70°C; IP67
- Ex tb IIIC T85°C or T135°C; Db Ta = -20°C to 70°C; IP67
UKEX (FM21UKEX0170X): Approved
- II 2 G Ex db IIB+H2 T6 or T4; Gb Ta = -20°C to 70°C; IP67
- II 2 D Ex tb IIIC T85°C or T135°C; Db Ta = -20°C to 70°C; IP67
Talk with our application specialist or a rep near you for sizing and materials requirements
- FC20 Flow Conditioner for use with insertion style FT4X
- FT4X Power Supply
- Flow meter cleaned and bagged for Oxygen service
- Certificate of Conformance
- Certificate of Origin
- Extra Instruction Manual
- USB Cable
- Teflon Ferrule Kit
- Stainless Steel Tags
- Retractors