Netel - Model ChromPlus 4000 series -Gas Chromatograph
FromNetel India Ltd.
Dual FID, TCD, NPD & ECD Detectors with four injectors to enhance analytical capabilities. Thermodynamically designed oven accommodates capillary and packed columns. Up to 5 individually controlled heated zones; up to 4500C for better method control. Optional accessories such as Head Space Sampler, Auto Liquid Sampler, Methaniser and Auto Gas Sampling Valve. Advanced Chromatography Software – “CLARITY” from Data Apex. Cost effective solution for QA/QC/Research applications. Exceptionally compact size for better space utilisation. PC control for all parameters.
Most popular related searches
packed column
gas sampling valve
flame ionization detector
gas chromatography
capillary column
sampling valve
liquid sampling
analytical instrument
chromatography software
pressure switch
COLUMN OVEN
- Size : H 290 mm x W 280mm x D 173mm
- Volume : 14 Ltrs
- Temperature : 5°C above the ambient to 450°C
- Ramp Rate : 1°C to 70 °C per minute
- No. of Ramps : 10 with storage of 20 methods
- Cooling Rate - 250°C to 5 0°C within approx. 4 minutes at 25°C room
- Temperature Gradient : 2°C max (on 200 mm dia circumference, 40mm from the sensor)
- Temperature Accuracy : + 1 % of set value from 50° to 450°c 5 Independent Heated Zones 450°C
PNEUMATICS
- EPPC ( electronic programmable pressure controller) for Carrier gas, Hydrogen, Air and Make-up gas.
- Pressure switch provided to cut heating of oven, injector, detectors heater power in the event of carrier gas flow depletion
- Differential Flow Controllers for carrier gas for Packed Column
- Constant flow or Constant Pressure facility for split/splitless injector port .upto 0 to 1000 kPa (0 to145 psi )
- Psi/kPa/bar pressure units conversion facility for supported carrier gas N2,H2,He,Ar
- Split ratio : 9999:1
INJECTION SYSTEM
- Single/dual Split/split-less (capillary column) injector port or single/ dual packed column injection port
- Temperature range settable up to 450°C. in the steps of 1°C
DETECTOR
FID
- High sensitivity flame ionization detector with auto flame ignition, Temperature range settable up to 450°C. in the step of 1 °C
- Dynamic range : 107
- Minimum Detection Level : <1.2pg C/sec of dodecane
TCD
- Dual path four Tungsten-Rhenium filaments
- Temperature range settable up to 400°C in the step of 1 °C
- Filament current range : 0-400 mA
- Minimum Detection Level : 10 uv/ppm(vol) toluene
- Filament temperature 150 - 450 °C in steps of 75°C with
- Filament protection circuit
NPD/FTD/TID
- Temperature range settable up to 450°C. in the step of 1 °C
- Minimum Detection Level : <0.1pg N/S C/sec (azobenzene) selective for nitrogen &<0.01pg P/S C/sec (malathion) selective for phosphorus.