THT Medor is an online Gas Chromatograph dedicated to the analysis of THT present in different gases.
Two versions of the instrument exist :
- THT Medor ppm (measuring at ppm levels)
- THT Medor ppb (measuring at ppb levels)
- Internal pressure & temperature monitoring
- Sample loop injection is made by automatic valve
- THT Medor uses a sulphur specific electrochemical cell for the detection of THT
- Online, continuous sampling
- No interference from other compounds
- Low maintenance instrument – detector life may be up to 10 years
- Automatic Validation of results by Internal Permeation Tube
- Modifiable threshold alarms – High / Low alarm for odorising processes
Chromatotec developed software system enables :
- Remote monitoring injection control
- Full traceability with on board archiving of results
- QC Set up and control of threshold alarms
- Export of data MODBUS / MGS1 / 4-20mA / 0-10V
- Multiple stream selector (up to 32 streams with one analyser)
- Explosion proof version Exp or Exd for ATEX, IECEx zone 1 and 2 group IIC T4 and also for CSA C1D2 group B , C & D T4
- Calculation modules (Average / Statistics / Odor index and more)
- Automatic data transfert through: Module for 4 outputs 4-20 mA (with 0 mA for instrument default) / 0 - 10 V / MODBUS RTU or TCPI IP or MGS1
- Nitrogen or air generator for safe and hasardous area
- 24 V DC power supply
- Electric selection valve to reduce air consumption
- Liquid injection valve from LPG up to condensates
- High concentration injection valve up to 5%
- Wall mounted box XXX934
- Liquid injection valve for LPG analysis
- Touch screen on the front panel for Exp version (only ATEX)
- External cylinder inlet for automatic calibration from external cylinder
- MFC for multipoint calibration from internal CALIB and/or from cylinder
- Zero method
Compounds Analysed:
- THT – TetraHydroThiophene and TBM Ter Buthyl Mercaptan
Detection Limit:
- ppm Model – 1 mg/m3
- ppb Model – 0.3 mg/m3
Detection Range:
- ppm model - 1 to 50 mg/m3
- ppb model - 0.3 to 3.0mg/ m3
- (Ranges adjustable depending on Application)
Relative Standard Deviation:
- RSD < 2 % on concentration over 48H
- RSD < 0.6% on retention time over 48H
Cycle Time:
- THT and TBM 180s (for one stream)
- THT and TBM 240s to 300s (for multi stream)
Supervisor:
- Embeded computer Windows® based with LCD display
- 128 GB of Hardware storage on SSD memory
Communication:
- MODBUS RTU included in standard
- Ethernet, remote control
Gas supply:
- Carrier Gas: N2 (3 bars): 10 ml/min
- Internal calibration: 50 ml/min (if selected)
- Sample inlet 1 bar (160 ml/min)
- Pneumatic valve 90 ml/commutation
Power supply:
- Main: 230V / 60Hz or 115V / 50Hz
- In case of power loss, the isntrument will restart automatically
Electrical consumption:
- Mean: 150 VA
Dimensions and weight:
Rack: 19’’ - (5U)
- Height: 222mm
- Width: 482mm
- Depth: 600mm
- Net weight: 22Kg
Exp version:
- Height: 800mm
- Width: 600mm
- Depth: 320mm
- Net weight: 40Kg