H2scanModel HY-OPTIMA 700B Series -Process Hydrogen Analyzer

SHARE

H2scan’s HY-OPTIMA 700B series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA 700B series is a solid-state sensor that is configured to operate in process gas streams with temperatures up to 60ºC. The HY-OPTIMA 700B series is ideal for hydrogen production and petrochemical applications where real-time measurements can enhance process plant efficiencies, diagnostics and maintenance management. The HY-OPTIMA® 700B Series inline hydrogen process analyzer is also designed for gas streams where real-time, hydrogen-specific measurements can enhance process plant efficiencies, improve yields, and reduce maintenance costs.

Most popular related searches

General Use Inline Hydrogen Process Analyzer

  • Solid state sensor for durability
  • Wide range of operating temperatures
  • Zero maintenance
  • Fuel Cells
    • H2 measurement on both anode and cathode side
  • Natural Gas
    • H2 in natural gas or biomethane
  • Industrial Gas Supply and Hydrogen Production
    • Air separation
    • Steam methane reforming
    • Electrolysis process streams
  • Laboratory
    • Research applications
  • Manufacturing
    • Metals annealing
    • Semiconductors
    • Oil hydrogenation

  • Highly reliable
  • Real time, continuous hydrogen measurement
  • Low life cycle cost
  • Tolerant of many harsh background contaminants
  • Easy to install and operate
  • No reference or carrier gases required
  • Minimal maintenance required
  • Non-consumable solid state technology
  • No cross sensitivity to combustible gases
  • Field-configurable settings
  • Verification Interval: 90 days
  • Product Life Expectancy: 10 Years
  • Field Calibration: Yes
  • Pressure: 0-2 bar gauge, 0-29.4 psi gauge
  • Operating Humidity: < 95% RH (non condensing)
  • Flow Rate: 0.1 to 10 slpm
  • Process Gas Temperature: -20ºC to 60ºC
  • Operating Temperature: -20ºC to 40ºC
  • Storage Temperature: -30ºC to 50ºC
  • Output Signals:
    • Analog: 4 to 20mA (or user specific mA) or 0 to 5 VDC (or user specific VDC)
    • Serial: RS232 or RS422
    • Relay Contacts1,2: 1A/30VDC SPDT
  • Input Voltage: 10 VDC – 26 VDC
  • Input Power: 15W
  • Dimensions: 9.3in (L) x 3.4in (W) x 1.4in (D)