Henan Yuantong Heavy Industry Machinery Equipment Co., Ltd.,

YuantongModel Q91Y Series -Heavy Hydraulic Shearing Machine

SHARE

The hydraulic shearing machine is a machine that uses a moving upper blade and a fixed lower blade, and uses a reasonable blade gap to apply shearing force to metal sheets of various thicknesses to make the sheets break and separate according to the required size.

Most popular related searches
  • Power: 74-460kw
  • Blade length: 1400-3000mm
  • Bin size: The width of the material box is generally the width of the blade, and the length is 6m or 8m.

It is suitable for metal recycling processing plants, scrap car dismantling plants, renewable resource material recycling industries, for various shapes of color steel tiles, bicycle racks, motorcycle racks, scrap car iron sheets, hydraulic oil drums, refrigerator iron sheets, TV casings, Various metal structures such as angle steel, channel steel, small briquettes, etc., are cut in cold state and processed into qualified charge.

Precautions for starting the metal hydraulic gantry shearing machine

  1. Start the shearing machine for a few cycles of idling to ensure that under normal conditions, test cuts of different thicknesses, from thin to thick. Ensure that the user is familiar with the shear performance.
  2. It is necessary to adjust the gap of different blades when the plate thickness is different during trial cutting. If the corresponding blade gap is not adjusted, the blade durability will be affected.
  3. Turn on the pressure gauge switch during the cutting process of the hydraulic gantry shearing machine and observe the pressure value of the oil circuit. The pressure should be less than 20MPa when cutting a 12mm plate. the user needs to comply with this regulation, and the material that exceeds the specified thickness and cannot be cut can not be cut, causing damage to the machine.
  4. Sound balance during operation. If the shearing machine has noise, stop and check.
  5. When the shearing machine is operating, the temperature of the fuel tank increases by 60 degrees. When it exceeds, it will shut down and rest.