Chromatotec Group

- Model C6C12 - Heavy Volatile Hydrocarbons Analyzer

From

0

Capable of anlaysing up to 32 compounds from C6-C12 (used in airmozone) or PAMS. The airmoVOC C6-C12 uses a valve with 1 sample trap. It also features a metalic capillary column. Miniaturization, sensitivity, mobility and flexibility are its main features.

MCERTS certified analyser for benzene measurement following EN 14662-3 norms

Everything from the sample port up to the data storage is integrated in a 19’’-rack 5U):

  • Uninterrupted sampling with pre-concentration on 1 absorbent tube
  • Gas chromatograph with 0.2 mm ID metallic column and programmable temperature gradient oven and pressure / flowcontrol of the carrier gas by piezo-valve
  • Before delivery the analyser is tested for one week by our quality control department.The Vistachrom software enables the user to visualize and store data on a PC. Furthermore it enables the user to recalculate, calibrate the instrument export data and to set-up measurement.

The software allows the calculation of retention time, area, mass or concentration profiles.

C6 to C12 analysis:

  • C6 (Hexane, Dimethylbutane) to C10 (Diethylbenzene, Naphtalene) and dodecane

Detection limit:

  • Tri-methylbenzene: 10 ppt or 0.05 μg/m3
  • Benzene: 10 ppt in standard 1 ppt with airmoVOC Expert

Detection range:

  • 0.05 to 45 μg/m3 for Tri-methylbenzene and Benzene - (A3)
  • 0,50 to 400 μg/m3 for Tri-methylbenzene and Benzene - (A2)

Note: Be careful with total mass and mass by compounds. Amplification 1: On demand to decrease the sampling volume.

Relative Standard Deviation:

  • < 0.3 % over 48h (RT)
  • < 3 % over 48 h (Conc.)

Results:

  • Data storage
  • MODBUS / JBUS communication protocol (option)

Cycle time:

  • 15 min, 30 min, 40 min, 60 min

Gas supply:

  • H2 (FID and carrier gas): 30 ml/min (inlet 2 bars; 1/16’’ swagelock)
  • Air (FID): 180 ml/min (inlet 3 bars ; 1/8’’ swagelock)
  • Sample inlet (vacuum pump) 1/4’’ swagelock

Sample volume:

  • 30 to 700 ml (programmable)

Power supply:

  • Main: 230 V / 115 V or 50 Hz / 60 Hz
  • Battery: 24 V (option)

Electrical consumption:

  • Mean: 150 VA, Peak 360 VA

Dimensions and weight:

  • Rack: 19’’ - (5U)
  • Height: 222 mm
  • Width: 482 mm
  • Depth: 600 mm
  • Net Weight: 22 kg

  • On-line results are transmitted via: MODBUS / JBUS or MGS1 communication protocol
  • AirmoVOC Expert 1 ppt
  • Automatic validation and calibration with internal CALIB
  • 24 V power supply
  • Hydrogen and zero air generator for transportable analysers
  • Multiplexer: 2 to 32
  • Purge module to extract VOC from water for online VOC in water analysis
  • Internal or external multipoint calibration and zero with CALIB MFC, XXXCYL MFC, airmoCAL MFC or airmoCAL D
  • Up to C16 with airmoVOC C6C16