MRUModel MGAprime -High End Flue Gas Emission Analyser

SHARE

High end flue gas emission analyser for emission monitoring of various industrial sites. Precise and very stable offset measuring technique by means of non dispersive infrared (NDIR) technique, for enhanced long time measurements. Up to 8 gas NDIR measurement: CO/CO2/C3H8/CH4/SO2/NO/NO2/N2O/H2 and oxygen with either long-life O2-ECS or O2-PM (paramagnetic cell). Remote control via smartphone or tablet using VCN server via LAN/WLAN (no remote control via MRU4u app). Wireless data transfer via Bluetooth dongle or WLAN dongle or via VNC server using LAN/WLAN.

Most popular related searches
  • Integrated, efficient dual heat exchanger gas cooler (Peltier type) with dual automatic condensate draining pumps
  • Using single beam through sample cell for NDIR measurements
  • Automatic zeroing by means of 3-way solenoid valve, internal sample flow volume measurement
  • Strong, regulated sample gas pump and easy replaceable, effective PTFE filter
  • Internal sample flow monitoring with display and alarm
  • Zero gas (ambient air) air inlet nozzle and passive VENT outlet of sample gas (for use inside laboratories)
  • O2 referencing (normalisation) to user settable value
  • Large fuel type list incl. self choose fuels with user definable parameters
  • Complete combustion calculation using country specific fuel type list
  • Automatic internal test and control of soft- and hardware functions
  • Automatic measurement incl. data logging function
  • 7” high-resolution (800x480 pixel) TFT colour display with swipe and touch technique, with LINUX operating system
  • Results stored in database - possibility to view entire measurement session in graphical form, create measurement reports, export data to CSV files, and more
  • PC communication via LAN - Ethernet
  • Data transfer to PC over LAN Ethernet (RJ45 socket) or USB
  • Analog outputs (8-channels), analog inputs (4-channels)
  • Modern and robust design, Aluminium enclosure with rubber molded impact protection for use in harsh industrial environment

Glas flow velocity and mass calculation by using a Pitot tube

8-gas NDIR module

CO - CO2 - NO - NO2 - N2O - SO2 - CH4 - C3H8

6-gas NDIR module (CH4)

CO - CO2 - NO - NO2 - SO2 - CH4

6-gas NDIR module (C3H8)

CO - CO2 - NO - NO2 - SO2 - C3H8

H2 - measurement

0...1.000,  overload up to 2.000 ppm

H2S-measurement

0...500, overload up to 2.000 ppm

Range extension CO (NDIR) to 100.000 ppm

Measuring range

  • O2: (paramagnetic) 0 ... 25,00 %
  • CO2: (NDIR) 0 ... 50 %
  • CO: (NDIR) 0...175 / 10.000 ppm
  • HC (CH4): (NDIR) 0 ... 500 / 10.000 ppm
  • HC (C3H8): (NDIR) 0 ... 200 / 5.000 ppm
  • NO: (NDIR) 0 ... 200 / 4.000 ppm
  • NO2: (NDIR) 0 ... 150* / 1.000 ppm *only possible with optional acid dosage box
  • SO2: (NDIR) 0 ... 150* / 4.000 ppm *only possible with optional acid dosage box
  • N2O: (NDIR) 0 ... 100 / 500 ppm
  • H2: 0...1.000ppm, Überlast bis 2.000ppm 0...10.000ppm, overload 20.000ppm
  • Fluegas temperature: 800°C, optionally 1.700°C
  • Ambient air temperature: 0°C ... 100 °C
  • Differential pressure: -120 ... +120 hPa
  • Flow Velocity: 3 ... 100 m/s

Dimensions and other data

  • Operating system: LINUX
  • Display: 7“ TFT (800 x 480 px) colour display, backlit, with touch pad
  • Data storage: internal 10.000 data sets, external USB stick
  • Interfaces: Ethernet, Bluetooth, WLAN, RS485
  • Printer: external thermal printer only
  • Battery capacity: Li-Ion , 96 W, for approx. 1 hour „stand-by“
  • Operating temperature: +5 ... +50 °C ; RH up to 95 % non condensing
  • Storage temperature: -20 ... +50 °C
  • Power supply: 86 ... 265 Vac / 47 ... 63 Hz / 105 W (analyser only)
  • Protection: IP20 (or IP42 inside transport bag)
  • Dimensions: 430 x 290 x 150 mm (w x H x D)
  • Weight: approx. 7,5 kg for minimal configuration