Dongguan Hitfar Power Technology Co., Ltd

HitfarModel ZC-EH3.5 -3.5KW Electromagnetic Induction Heater Main Control Board

SHARE

Wire Connection Instruction of Electromagnetic Induction Heater. Induction heater R/S interface is for soft start interface, the heater start to work when connect the 2 interfaces and stop working when disconnect (of course, we can make it vice versa, disconnect 2 interface to start to work, and connect to stop working by setting through F-02). Normally, connect to output of temperature control.

Most popular related searches
  1. R/S interface can be used for external on/off for start or stop working.
  2. LED interface is for connecting to external 12V-24V DC working light
  3. R/S interface can start directly when not connect to external soft start on/off. The heater start to work when press the right below red button last for 3 seconds and stop work by press once again.

Descriptions

  • Model No.: ZG-EH3.5
  • Rated Power: 3.5KW, 220V-1P, 50hz or 60hz
  • Induction Coil Request: Loading Inductance of 80-100uH, coil wire requested of 6mm2 copper core`15-17meters long
  • Model NO.: ZC-EH3.5-B
  • Rated Power: 3.5KW
  • Rated Input Voltage: AC 220V-1P
  • Input Current: 15-16A
  • Working oscillation frequency: 3-40KHZ
  • Loading Inductivity Value: 80-lOOuH
  • Coil wire request: 6mm2 copper core`l 5-17meters long
  • Working Voltage Range: 180V-240V
  • Working Environment Temperature: -20SC~60SC
  • Heating Exchange Rate: :95">
  • Current £ Voltage Working Condition: Constantly
  • Loading: >95%
  • ICBT/MOSFETTemp. Protection: 75°C
  • Work mode: automatically working, constantly heating
  • The waves rushed to protect: 1500V
  • Anti-clutter: 4000V