The HORIBA SMA-371 data logger can be used both, in the online and in the offline operating mode. In the online operating mode you attach the data logger directly to the serial interface of the PC. In this case only instantaneous values are processed. On the basis of the instantaneous values the further processing takes place in EDA-2000. If only the measuring data from a HORIBA PG-250 and no further analogue values are required, the HORIBA PG-250 measuring instrument can be attached directly to the PC. In the offline operating mode, data acquisition and data storage are independently from the PC.

Most popular related searches
  • Data acquisition and verification of the raw data from the PG-250 instrument and additional analog inputs, maximum 16 input channels.
  • Calculation of average values, setting time frame from one minute up to one hour.
  • Storage of the average values in the battery back-up internal memory.
  • Support of 8 different measuring sites.
  • Configuration and processing of measurements with EDA-2000.
  • Storage capacity: 460 hours with 16 components at a time frame of 30 minutes, 15.5 hours with 16 components at a time frame of one minute.
  • 7 analog inputs for current or voltage input port for the connection of the Horiba PG-250.
  • Serial port for the connection to a PC for configuring and transfer of the measuring data.
  • Serial port for the connection of the Horiba PG-250.
  • 8 binary TTL inputs.
  • Control unit consisting of: LCD display (2 x 16) and 5 input keys
  • Serial ports for the connection to a PC for configuring and transfer of the measuring data and for the connection of the Horiba PG-250
  • Analog inputs for current or voltage inputs: 7
  • Binary TTL inputs: 8
  • Data acquisition and verification of the raw data from the PG-250 instrument and additional analog inputs, max 16 input channels
  • Conversion of the raw data into a second physical unit
  • Calculation of average values with an averaging time of one minute up to one hour
  • Storage of the average values in the battery back-up internal memory
  • Storage capacity: 460 hours with 16 components and an averaging time of 30 minutes.
    15.6 hours with 16 components and an averaging time of one minute
  • If fewer components are configured, the storage time increases accordingly
  • Support of 8 different measuring sites. With each start of a measurement the selected measuring site is assigned to the stored average values