i-Zone - Model iZ-T25 -Touch Screen Control Panel
Our i-Zone Touch control panel can simultaneously monitor up to 25 of our Water, Oil, Refrigerant gas, Temperature, and Humidity detectors. Two pulse flow meters can also be monitored, with the facility to control a solenoid valve. The use of ZLM-50 leak locating modules allow the location of water leaks to be pinpointed anywhere along the cable. Built in Help screens increase this panels ease of use. Programmable volt-free contacts, and a Modbus TCP/IP output give this panel greater BMS connectivity.
The i-Zone Touch Control Panel is suitable for wall mounting. It is constructed from mild steel, and has a durable powder coated finish.It features a 7 inch full colour LCD Touch screen, and is capable of monitoring the full range of ‘Aqualarm’ detectors for water, fuel oils/chemicals, temperature, humidity, refrigerant gases and 2 x pulsed flow meters for incoming mains water supplies. 25 detectors/zones can be monitored via the current addressable CAN network, with planned future expansion to a RS485 network and a 433 MHz wireless network.
The Control Panel has 3 levels of use, Level 1 User level, Level 2 PIN protected Operator level, and Level 3 PIN protected Engineer access. In any alarm condition a 97db (at 1 metre) audible alarm will sound. The default detector identification is ‘Zone 1’, ‘Zone 2’ etc, however these can be customer programmed to read site specific locations, eg ‘Zone 1 Comms Room AC Unit 1, using the touch screen keyboard. Each zone can be independently configured to automatically trigger panel relays, beacon & sounder outputs, and to enable, or disable the panel and detector sounders. The Control Panel can store 100 events logs, which are protected by a non-volatile memory.
The system has an automatic Daylight saving setting to change times twice a year in line with UK protocols. This can be deactivated for export models. The Control Panel can also monitor a maximum of 5 ZLM-500 modules (max100/m network cable), before a separate power booster box is required, this will result in a single system monitoring 2500 metres of detecting cable. With this type of detector connected, in an alarm condition the display will show a meterage reading accurate to +/- 1 metre to the point of contact water has made with the cable. Features of the Control Panel include a MUTE button, ISOLATE detector button, and RESET button. The SHOW ME feature allows the user to view a ‘pinch to zoom’ electronic map of the location of the alarm. A HELP button will display information to aid users in understanding information being displayed. Detector /Zone parameters can be adjusted/set/changed by level 2 & 3 users. The system is fitted with 2 x sealed rechargeable lead acid batteries to support the system in a mains power down/switch over periods. When power/mains is reinstated the system will automatically restart. For remote signalling the Control Panel is supplied with the following outputs as standard: - MODBUS TCP/IP, five-zone relay contacts, which can be level 2&3 programmed to signal with any zone, 12v powered contacts to activate a sounder/beacon, repeater panels, 12 & 24v powered auxiliary outputs, and a 24v @ 8 amp relay for activation of a flow meter solenoid valve (note – this is NOT a powered relay). For safety, the Control Panel is fitted with a key operated door lock and ‘Power off’ door switch.