Ecodas - Model T700 -Infectious Waste Shredding and Sterilization
Our patented process is designed to shred and sterilize infectious waste to reduce its volume, and render its components unrecognizable all in one fully enclosed and automated, stainless steel, system. It combines shredding, direct steam and high pressure to treat infectious materials.
The contaminated waste is loaded into the upper chamber where a heavy-duty, high-torque, low speed shredder reduces the waste into small pieces.
Using gravity, the processed material drop into the lower treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3.5 bar (51 psi) for 10 minutes. The operating and treatment conditions are continuously monitored and validated to achieve complete sterilization (Microbial inactivation = 108).
After the cooling process, the final product is volume-reduced (by up to 80 %), rendered unrecognizable and safe to recycle or to dispose as ordinary municipal waste.
The 30 minutes duration of an average cycle process is fully automated and totally monitored. A computerized control system scans the process and automatically prints a batch report at the end of each cycle with the essential sterilizing parameters for accurate record keeping.
GENERAL CHARACTERISTICS
- Dimensions ( L x l x H )
- Dimensions ( L x W x H ) 460x 430x 520 CM
- 15.1x 14.1 x 17.1 FT
- Shipping Weight 2500 KG
- Max weight when filled with water For a special hydraulic test 4700 KM
- Stress 2.0 KG/CM2
- Steam Pressure 8 BARS
- Max Steam Flow 230 KG/H
- Compressed Air 6 BARS
- Electricity 380V /Three phase 20 KW
OPERATING CHARACTERISTICS
- Average Cycle Time 30 MIN
- Process Volume Capacity 700 LITERS
- Average Waste Density 100 – 150 KG/M3
- Average Process Weight Capacity
- Average Process Weight Capacity 70-105 KG/CYCLE
- 155-231 LB/CYCLE
- Microbial Inactivation 108
- Waste Volume Reduction 80%
CONSUMPTION / CYCLE
- STEAM 18 KG
- ELECTRICITY 3.5 KWH
- WATER 20 LITERS