Olpas
  1. Companies
  2. Olpas
  3. Products
  4. Olpas - Model OTU-IWAA-001 - Inline Dry ...

OlpasModel OTU-IWAA-001 -Inline Dry Solids Measurement Sensor for Iron Water and Sludge

FromOlpas
SHARE
The Olpas Dry Solids/Dry Matter Sensor is designed for inline measurement in iron water and iron sludge. Featuring ultrasound technology, the sensor offers high reliability and accuracy in challenging conditions where traditional optical and microwave sensors fail, due to the opaque and conductive nature of iron sludge. Capable of measuring dry solids concentration from 2% to 30%, it is insensitive to fluid color, velocity, and solids' structural changes. The sensor is pre-calibrated, with options for RS485 Modbus RTU communication, and integrates seamlessly with existing IoT solutions or PLCs. Installation offers flexibility with mounting options, including inline flange and chain mounting, and requires a minimal depth of 60mm for effective measurement. Constructed with durable materials like Stainless Steel 316L and providing easy maintenance requirements, Olpas sensors represent an efficient solution for water treatment facilities requiring high-precision solids concentration monitoring.
Most popular related searches

Dry Solids / Dry Matter sensor for Iron Sludge / Iron Water. 

Advantages compared to optical sensors 

  • The high absorption of iron sludge interferes interferes with the transmission of light, making it difficulet for optical sensors to optain accurate readings

  • Iron sludge can be highly opaque, which makes it unsuitable for optical measurement technology

  • Olpas sensors are not sensitive to changes in fluid colour

  • Olpas sensors are not sensitive to solids form and structure

  • Reduced sensor fouling: Iron sludge can cause fouling of the optical sensor surfaces. The buildup of sludge on the sensor can obstruct the light path and require frequent cleaning and maintenance to ensure accurate measurements; which is not needed for the Olpas Ultrasound Measurements.

 

Advantages compared to microwave sensors 

  • The conductive nature and dielectric variability of iron sludge heavily distort the sensor readings and reduce measurement accuracy. 

  • No need for recalibration every 7 days

  • The Olpas Tentacle sensor can be place both in the basin or silo or inline

Measurement Principle:

Ultrasound measurement

 

Measuring Range: Between 2 %DS and 30 %DS

Accuracy: [Contact us for more information regarding your specific measurement]

 

Independence/insensitive to:
Fluid colour and fluid velocity
Solids form and structure

Suitable for measurements in Iron Water (cfr. "Waterijzer", iron sludge, ferric (hydr)oxide) 

Standard maintenance

Cleaning with a cloth

Frequency depending on installation specifications and environment

[Get in touch for more information and to discuss your specific requirement]

 

Yearly maintenance

Thorough inspection and calibration checkup (45 min)

Delivered with standard calibration between 2% - 30%DS
Scaling factor and offset can be set. 