IntuitionModel h -Single-Zone Heating & Hot Water Control System

SHARE

OWL recommends that all Intuition Smart Heating Controls are installed by a qualified heating engineer. Not all boilers can accept external thermostats. Please contact your boiler manufacturer to find out if your boiler is able to accept an external control.

Most popular related searches

Modules

  • OWL Intuition-c consists of the following:
  • 1x Network OWL Gateway
  • 1x Intuition Room Sensor
  • 1x Wireless Relay Unit

Options

  • OWL Intuition-cw can support the following additions:
  • Up to 8 additional Intuition Room Sensors to support additional heating zones (where the heating system has separately controllable zones)*
  • Up to 3 additional Intuition Relay Units to support additional wirelessly controlled heating zones (where the heating system has separately controllable zones)*
  • Electricity monitoring functionality via a 3-channel Transmitter unit with standard/large sensors (see Electricity Monitors ACCESSORIES tab)*
  • Smart thermostat and tank stat allow web based control of a single heating zone and single hot water zone. (additional heating zones can be added - see Options)
  • Programmable timeclock and temperature control; which intelligently calculates times to turn on to maximise benefit.
  • Retrofits existing wired heating and hot water controls.
  • Access via mobile device or PC to smartphone app or web dashboard - wherever you have internet. Turn the heating on if you`re coming home early; or turn it off if you`ve left it running.
Technical Specifications:
  • Network OWL – 868MHz & 433MHz
  • Heating Controls – 868MHz
  • Operating range up to 50m (In free space)
  • Storage conditions: -25°C to +65°C
  • Relative humidity: 25% to 95% non-condensing
  • Operating temperature: 0°C to 40°C
  • Ingress protection: IP30
Standards Compliance
  • IEC 60730-1:2001 / BS EN 60730-1:2001
  • BS EN 55014-1:2006+A1:2009
  • BS EN 55014-2:1997
  • ETSI EN 300 220-1 V2.1.1 (2006-04) / ETSI EN 300 220-2 V2.1.2 (2007-06)
  • ETSI EN 301 489-1 V1.8.1 (2008-04) / ETSI EN 301 489-3 V1.4.1 (2002-08)
  • R&TTE - WEEE Directive, RoHS, Battery Directive

Includes 

  • Network OWL Gateway,
  • Tank Sensor [TBT-E3H] (Battery powered, with Comfort (+), Standby & More H/W buttons),
  • Room Sensor [RBT-3C] (Battery powered, with Comfort (+), Standby & Away buttons),
  • back plate x 2,
  • safety wiring cover x 2, 
  • 4 x AAA alkaline battery, 
  • Installation Instructions.