Labocon Systems Limited
  1. Companies
  2. Labocon Systems Limited
  3. Products
  4. Labocon - Model LAAS-102 - Atomic ...

LaboconModel LAAS-102 -Atomic Absorption Spectrophotometer

SHARE

Labocon Atomic Absorption Spectrophotometer LAAS-100 Series spectrophotometer, which offer superior base line stability of 0.002A/30min with advance optical system to ensure simple and reliable solution for trace elemental analysis.

Most popular related searches
  • Gas Control
    • Software controlled quick gas conversion and safetyprotection device used to analyse airacetylene flame and nitrous oxide-acetylene flame
  • Spray Chamber Metal Glass Spray
    • Burner Corrosion resistant titanium burners available for both air/acetylene and nitrous-oxide acetylene
  • Safety System
    • Safety interlock mechanism that monitors the burner type, burner fitted, gas pressures. Flame on/off sensors; Power failure automatic shutdown. Liquid trap system, pressure relief plug and flame shield to protect from UV radiation
  • Czerny-Turner grating monochromator
  • Grating density of 1800 lines
  • Anti-corrosive plastic sprayed chamber
  • Metal glass spray set
  • Photomultiplier tube as detector
  • Optimized 3D lights for maximum energy
  • Can distinguish between manganese light
  • 0-10mA and 400Hz four lamps and optional six lamps with auto switch
  • Air cooled pre-mixed 100mm single slit titanium burner
  • Less than 1% precision
  • Air-acetylene and oxygen enriched air-acetylene flame method
  • Hydride generation spectrometry
  • Automatic calibration, curve fitting and concentration calculation
  • Automatic calculation of average concentration, standard deviation, relative standard deviation
  • Acetylene gas leakage alarm
  • Rapid and convenient test results opened in office software
  • Software remote control to solve technical problems
  • Windows XP/Vista operating system

Labocon Atomic Absorption Spectrophotometer LAAS 100 series is widely used in analytical chemistry protocols, applications such as food and drug safety, clinical diagnostics, petrochemical, agricultural, environmental monitoring.

  • RS232 software
  • Graphite tubes
  • Graphite furnace system
  • Hydride generator
  • Nitrous oxide generator
  • Nitrous oxide regulator
  • Acetylene regulator
  • Recirculating cooling water system
  • Printer
  • Wavelength Range: 190-900 nm
  • Wavelength Accuracy: ±0.25 nm
  • Wavelength Repeatability: 0.05 nm
  • Spectral Bandwidth: 0.2, 0.4, 1.0, 2.0 nm
  • Temperature Range: 10-35°C
  • Working Humidity: ≤80%
  • Resolution: <20%
  • Baseline Stability: 0.002A/30min
  • Characteristic Concentration Limit: Cu: 0.025g/ml/1%
  • Detection Limit: Cu: 0.006g/ml
  • Background Calibration: -
  • Overall Dimension: 1000x400x470 mm
  • Weight: 70 kg
  • Power: 150 W
  • Power Supply: 220V 50Hz
  • Catalog No.: 9523127164