LeadClear - Ultra Translucent Lead Abatement Paint
LeadClear is a premium performing, translucent, matte finish, water-based, ultra low VOC, non toxic, modified acrylic coating designed to permanently abate lead paint via encapsulation as per ASTM E1795 requirements. LeadClear is specically formulated to adhere impeccably to existing coatings while preserving the aesthetics of the components & areas its being applied to such as walls, moldings, baseboards, stair stringers, posts, frames, etc. that require lead abatement.
Feel free to contact us for any of your protective coating needs such as (Interior, Exterior, floor, Commercial, Marine, Structural Steel, Tanks, Plants, structural & ornamental steel etc.
lead clear paint astm resultsLeadClear is a premium performing translucent, matte finish, water-based, ultra low VOC nontoxic modified acrylic coating design to permanently abate lead based paint via encapsulation method as per ASTM E1795 requirements.
LeadClear is specifically formulated to adhere impeccably & abate existing coatings which contain lead based paint.
LeadClear goes on smooth “milky white“ and dries with a translucent, matte, see-through clear finish. LeadClear can also be utilized as an encapsulating primer which can be over coated with desired color(s) & finishes.
LeadClear has undergone and successfully completed all phases of testing and meets or exceeds the vigorous ASTM E 1795 “Standard Specification for Non-Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings” requirements.
(All test results listed on clickable icons below)
Please do your due diligence. Don’t get sidetracked by terminology used by others such as “lead sealer” etc. including testing data which is a fraction of what it truly required. Simple: If ASTM E1795 is not mentioned in the product’s description is it worth using?
- CORROSION RESISTANT
- MOLD RESISTANT
- UV RESISTANT
TO ACCESS LEADCLEAR DATA SHEETS & TEST RESULTS PLEASE CLICK LABELED ICONS AT BOTTOM OF PAGE
DUE TO THE COMPLEX & COSTLY NATURE OF PRODUCTION, PACKING, SHIPPING & HANDLING, LEADCLEAR CURRENTLY CANNOT ACCEPT RETURNS. PLEASE SHOP WISELY & EFFICIENTLY”- TYPE: Water-based acrylic
- FINISH: Matte
- Color: Milky white (wet) Translucent (dry)
- Mixable with other products: no
- Paintable: yes
- Sizes: 1, 5-US gallon containers
- Disposal: in accordance with local, state & federal regulations
- Application Equipment: airless spray, brush, roller
- Mixing: ready to use, mix thoroughly
- Drying Time: 2 to 6 hours to touch depending on ambient temperature
- Full Cure: 11-15 days depending on ambient temperature
- VOC: <195 g/l
- Clean up: soapy water
Spreading Rate to Achieve Required 12-14 Mils Dry Film Thickness

Spreading Rate to Achieve Required Dry Film Thickness – 50 sq.ft/gal
Note: Spreading rate does not include any loss during application process.
RECOMMENDED USES:
- WALLS: walls, chair rails, baseboards. DOORS: doors, casings.
- WINDOWS: apron, casing.
- CEILINGS: ceilings without calcimine.
- STAIRS: balusters, newel posts, stringers
- OTHER: curved wood surfaces.
- CABINETS: nonfriction surfaces.
- DRAWERS: nonfriction surfaces.
USES NOT RECOMMENDED:
- WALLS: walls with chalking or calcimine DOORS: door jambs
- WINDOWS: (see prohibited list)
- CEILINGS: ceilings with calcimine
- OTHER: friction areas
- CABINETS: friction areas
- DRAWERS: friction areas
PROHIBITED: ?oors, stair treads, thresholds, as well as the sashes, parting bead‘s, window wells, and the interior/exterior or header stops of movable windows.
SURFACE PREPARATION: All surfaces must be clean, sound, dry & free of dust, rust, grease, oil, mildew & loose particles before application. A licensed deleader must remove all ?aking and peeling paint down to a sound surface. Repair damage with a joint compound and smooth over with a damp sponge to remove excess compound and blend into surrounding wall surface. Remove all oil, grease, wax, smoke residues and other contaminants by washing with a suitable cleaner and rinsing with clean water. Remove mildew by washing with a solution of TSP (tri-sodium phosphate) in 1 gallon of water and add 1 quart of commercial bleach. Wear gloves and protective eyewear if using bleach solutions. For high-gloss surfaces, wet scour with TSP or a strong detergent substitute and water solution using course steel wool to eliminate any gloss. Thoroughly remove by washing any residual scouring material, detergent or other surface preparation material, and dry completely prior to application. Although no special primers are required, there may be occasions where primer would be bene?cial in the overall performance of the coating. Prime water stains with stain blocking primer, prime chalking with penetrating chalk primer, prime bare wood within a enamel undercoater; prime drywall with a quality acrylic primer & sealer.
ENCAPSULANT APPLICATION: Apply in the multiple coats to achieve total thickness of 20 mils (wet). Use a wet mil gauge when applying product. Do not apply if ambient temperature is below 45°F. Airless spray application in two costs (each 10-12 mills) is recommended for best results, including a smoother dry ?lm. Use .017 to .019 inch ori?ce & a 60 mesh screen. If applied with a brush or roller, multiple coats are required to achieve the required thickness. Expect 10-12 mils per coat by brush and 10-12 mils per coat by roller. Use a polyester or polyester/nylon brush. Use a high-quality tapered trim brush with the ?lament density to achieve a smooth ?nish on all trim work. Application to a large smooth or any size rough area should be performed with a quality roller cover with a half inch cover to three-quarter inch nap. Regular paint topcoats may be applied over services that have been sprayed, rolled or brushed with LeadClear if desired.
OCCUPANCY DURING APPLICATION: occupancy is permitted during brush or roller application, but not in room or interior area being encapsulated. For spray application, occupancy is prohibited during the day for work site safety reasons only. Occupants may return at the end of the workday.
OCCUPANCY AFTER APPLICATION: Yes. Use adequate ventilation for ?rst 24 hours after application.
CAUTIONS: did you use adequate ventilation. If respiratory irritation develops, increase ventilation or where respiratory protection. Use molded polymesh shell dust and mist respirator – MSHA, NIOSH, Approval No. TC-21C-287 or equivalent during spray application. Avoid contact with eyes and skin. Wash hands thoroughly with soap and water after using. During application wear gloves and safety goggles.
WARRANTY: LeaClear has limited product liability for 20 years. The purchaser shall notify Tara JV Corp. within 30 days after purchase to advise of any assumed manufacturing defects.
CARE AND MAINTENANCE: LeadClear will not protect occupants from ingestion of the encapsulated lead based paint if surface is damaged, broken, or abraded. Surfaces coated with the LeadClear must be inspected routinely for holes, cracks, dents, peeling services, bubbles, or any other defects; including water damage. Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard.
LeadClear PAINT can be applied on virtually all sound interior or exterior substrates such as: Wood, Plaster Walls, Gypsum Board Walls, Brick & Mortar Walls, Concrete, Ceramic, Stucco, Steel, Cast Iron & Aluminum.
Wet Appearance: Milkier Translucent Liquid
Dry Appearance: Translucent
Weight: 8.25-8.75lbs/gal
Speci?c gravity: 0.99 to 1.050
VOC: Less than 195 GMS/lt.
Dry Time @75 f: 2 – 6 hrs.(Depend upon substrate and weather condition)
Clean up: Water
Solid By Wt.{28fbbca4d5e380ff11c49cfcf258524327390f8bd5020b9c03575f0942ab537b}: 30 – 40 {28fbbca4d5e380ff11c49cfcf258524327390f8bd5020b9c03575f0942ab537b}
Solid By Vol.{28fbbca4d5e380ff11c49cfcf258524327390f8bd5020b9c03575f0942ab537b}: 28 – 38 {28fbbca4d5e380ff11c49cfcf258524327390f8bd5020b9c03575f0942ab537b}
Viscosity: 65 kU Minimum.
Recommended Coat: 2 Coats.
Flash Point: Non Combustible
Shelf life: 2 years
PRODUCT TESTING
ASTM E-1795
ASTM E84
Meets requirements to be utilized as a permanent method for abatement of lead-based paint.
GALLON KIT SIZES
1 & 5