Lenntech - Model LennRO mini -Tap Water Reverse Osmosis Systems for Small Flow 100 l/h & 200 l/h
Lenntech Mini Reverse Osmosis Systems provide low conductivity water from tap water*. Lenntech units are ready-to-use, skid mounted and easy to operate. Compact design, low energy demand and high recovery; Fully automatic system, microprocessor controlled.
- 5-micron cartridge filter;
- High pressure pump, brass pump head;
- Permeate conductivity indicated in the front panel display;
- High performance Dow membranes;
- Fiberglass pressure vessels;
- Permeate and concentrate flow meters;
- Pressure indicators: feed pressure, high pressure and concentrate pressure;
- Low pressure switch before the HPP;
- Controller for fully automatic operation;
- PVC piping, flexible braded hose, PE hose;
- Needle valves, inlet valve, high pressure pump and appendages in brass.
- Parameter: Range
- Total dissolved solids: Max. 500 ppm
- pH value continuously: 2-11
- pH short time during cleaning: 1-12
- Dissolved iron: Max 0.05 ppm
- Dissolved manganese: Max 0.05 ppm
- Chlorine (continuously): 0 3:rn
- Oil and grease: 0 ppm
- Silt Density Index SDlis: <3
- Turbidity: <1 NTU
- Temperature: Min. 15°C-max. 25*C
- Pre-pressure: Min. 2 bar - max. 4 bar
- Softener as a pre-treatment for high hardness water
*) Water quality resembling tap water quality (low brackish water) can also be used as feed water, consult a Lenntech engineer with the water analysis of your feed water source
**) These data are given for information purpose only. They are subject to modifications depending on the water quality.

Reverse Osmosis units often required pre-treatment for the following parameters:
- Suspended solids
- TOC, COD/BOD, oil and grease
- Iron and manganese
- Hardness removal/ reduction
Lenntech provides all kinds of pre and post treatment required before and after your RO, according to your water analysis and process requirements. Please contact us for further information.