The Multilink® Life Saver roof was rigorously tested against the competitions chimney and shielded style of cabinets. The Life Saver continuously outperformed the competition with an inside temperature that was around 20% cooler. All tests were witnessed and certified by Cincinnati Sub Zero (CSZ), an independent testing organization.
1 Hour Reading
After 1 hour the Life Saver™ cabinet came in at 14.6°F cooler than the Stove Top unshielded cabinet and 20.2°F cooler than the Stove Top Chimney cabinet.
3 Hour Reading
A mid range reading showed the Life Saver™ cabinet still standing up to the heat coming in at 24.1°F cooler than the Stove Top Chimney cabinet and 25°F cooler than the Stove Top Unshielded cabinet.
6 Hour Reading
At the hottest reading point the Life Saver™ cabinet showed it was still superior, standing 25.7°F cooler than the Stove Top Unshielded cabinet and 26.2°F cooler than the Stove Top Chimney cabinet.
Cold/Ambient Air Intake
Multilink's cabinets are designed to intake cold/ambient air at the base of the cabinets.
Hot Air Rises
As the air heats up it starts to rise due to head dissipation. Built in tray venting helps the hot air rise efficiently.
Exhaust
The ambient air reaches the Life Saver™ roof and is exhausted out at the industry's highest rate, keeping your electronics safe and secure.