- Home
- Companies
- MadgeTech, Inc.
- Products
- MadgeTech - Model UltraShock - Data ...
MadgeTech - Model UltraShock -Data Logger
The UltraShock is a temperature, humidity, pressure and tri-axial shock data logger. Includes certificate of conformance.
The new UltraShock contains powerful improvements and an all-in-one functionality, allowing it to replace all current shock models and their capabilities. New refinements also include a smaller, lighter design and LED status indicators.
Additional features include a significantly improved battery life and the use of a USB-C cable, making it easily rechargeable. Each UltraShock purchase contains an AC adapter and USB cable, eliminating the need for an additional interface cable.
The UltraShock is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
General
Memory: 4,000,000 readings (660,000 per channel, all channels in use)
Reading Rate:
- 1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure & humidity sampled approx. every
- 2 seconds at intervals shorter than
- 2 seconds. Otherwise, sampled at the reading rate.
Battery Life: 90 days typical at 64Hz rate
Material: Anodized aluminum
Dimensions: 3.4 in x 1.7 in x 1.3 in
(86 mm x 43 mm x 33 mm)
Operating Environment: -20 ºC to +60 ºC, 0 %RH to 95 %RH non-condensing
Required Interface Package: USB (type C cable required); 1MBaud
Approvals:
- CE compliant
- EMC Directive 2014/30/EU
- RoHS Directive 2011/65/EU
- IP Rating 64
Temperature
Sensor: Semiconductor
Range: -20 ºC to +60 ºC
Resolution: 0.1 ºC
Accuracy: ±0.5 ºC (+0 ºC to +50 ºC)
Humidity
Sensor: Capacitive Polymer
Range: 0 %RH to 95 %RH
Resolution: 0.1 %RH
Calibrated Accuracy: ±3 %RH (±2 %RH typical at 25 ºC)
Specified Accuracy Range: 0 °C to +50 °C; 20 %RH to 80 %RH
Pressure
Sensor: Semiconductor Strain Gage
Range: 100 to 1300 mbar
Resolution: 0.05 mbar
Calibrated Accuracy: ±1.5 mbar at 25 ºC; at 750 mbar
Shock
Accelerometer Type: MEMS Semiconductor
Acceleration Range (g): ±15 g/±100 g/±300 g
Acceleration Resolution (g): 0.02 g/0.05 g/0.2 g
Calibrated Accuracy (g): ±0.3 g/±2.0 g/±6.0 g
Sampling Rate: 1000 Hz
Accelerometer Freq. Resp.:
- >1000 Hz (15 g)
- >500 Hz (100 g, 300 g)
Reading Rate:
- 1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure & humidity sampled approx. every
- 2 seconds at intervals shorter than
- 2 seconds. Otherwise, sampled at the reading rate.