maMoS - Modular Stationary Gas Analyser
From Stationary Analysers
Small in size, yet very skilful analyser – it has the best capabilities/price ratio. maMoS is our alternative for large, intricate CEMS systems, as it does not fall behind them concerning functionality and abilities, and is far ahead in terms of expenses. It has modular construction, and many add-ons, that makes it easy to adjust to a very specific, individual application. Powerful PC software allows to adjust many aspects of the work with the analyser very individually (work schedule, analogue outputs' behaviour, data presentations, and more...)
Main Features:
- Standard configuration consists up to 6 sensors (NDIR and/or electrochemical).
- Up to 8 sensors in an extreme, unique configuration.
- NEW option: Large display with backlight, 4 lines x 20 characters
- Different types of gas dryers to fit the customers needs.
- Compact, Split and Twin split configurations.
- Data-logger with SD card for results’ collection.
- Analogue outputs (both current and voltage) to control external devices.
- Digital and analogue inputs to pass signals from external devices, to trigger maMoS actions.
- Communication with PC via different interfaces (USB, LAN, RS485 and MODBUS).
- Different work modes to select from (continuous measurements, work with scheduler, measurements triggered with digital input, “work in-turns” - allows to measure from two different sources, and more...).
- Powerful PC program to adjust the analyser's settings and to view the results.
- Rich offer of add-ons and accessories.
- NEW option: Possibility to work with heated hoses. Standard lengths: 3m 5m, 8m for 115VAC and 230VAC supply. Other hoses upon request.
Split Configuration
Analyser with a single gas channel is basic configuration of the device
The second (additional) gas channel is enabled for shorter time during the measurement phase. The additional gas channel is dedicated for the ”fragile” sensors, where they are protected against too long exposure to the gas. This way the life-time of the fragile sensors is prolonged.
Bio-measurement is a typical application for the double gas channel configuration - then the primary gas channel holds sensors CO2, CH4, O2, and the additional gas channel holds the H2S sensor that is recognised as a fragile one.
Analyser designed to work with overpressure with a single gas channel. Configuration can be used in installation with slight overpressure (<1.8bar)
Twin split configuration - this version is based o...
- Twin split configuration - this version is based on compact configuration, but one MD3 dryer with its own power supply is added on a separate mounting plate.
- Allows to perform measurements from two different locations (each dryer is installed near the measurement place). maMoS measures in turns - one cycle per location.
Twin split configuration - analyser and two gas dr...
Twin split configuration - analyser and two gas dryers, each on its own mounting plate, each equipped with a power supply module.
Allows to perform measurements from two different locations (each dryer is installed near the measurement place). maMoS measures in turns - one cycle per location.
The second (additional) gas channel is enabled for...
- The second (additional) gas channel is enabled for shorter time during the measurement phase. The additional gas channel is dedicated for the ”fragile” sensors, where they are protected against too long exposure to the gas. This way the life-time of the fragile sensors is prolonged.
- Bio-measurement is a typical application for the double gas channel configuration - then the primary gas channel holds sensors CO2, CH4, O2, and the additional gas channel holds the H2S sensor that is recognised as a fragile one.
Customer reviews
No reviews were found for maMoS - Modular Stationary Gas Analyser. Be the first to review!