Mass Flow Controller for gases with pressure compensation and integrated display: Direct thermal mass flow measurement. High accuracy. 10 pre-installed gases. Bright, graphical OLED display. Digital or analog output; alarm and counter functions. High precision needle valve with pressure compensation.
Most popular related searches
mass flow control
mass flow
flow control
gas mass flow control
needle valve
mass flow monitoring
gas mass flow
thermal mass flow
gas monitoring
gas mixture
Pre-installed ranges
Ranges: Flow range (relative Air)
- Range 1: 20 mln/min .. 200 mln/min (sccm)
- Range 2: 20 mln/min .. 100 mln/min (sccm)
- Range 3: 20 mln/min .. 50 mln/min (sccm)
Pre-installed gases
Gases: min. range .. max. range
- Air, N2, O2 and CO: 20 .. 200 mln/min (sccm)
- Clear indication in:
- actual flow rate (bar graph and value)
- desired flow units
- type of gas
- totalised flow
- Bright, wide-angle OLED display
- Free of parallax error
- Virtually independent of temperature and pressure variations
- Low pressure drop
- Wide flow ranges
- Fast response
- High accuracy
- Electronic output:
- Analog (0 .. 5 Vdc)
- RS-232 interface (with FLOWBUS)
- Modbus-RTU/ASCII interface
- Configurable password protection
- Alarm and counter functions
- Relays
- Multi Gas / Multi Range
- 10 Pre-installed gases
- Membrane operated valve
- High resolution needle valve
- Digitally calibrated
- Free software tools
- MASS-VIEW flow controller
- packing box
- 9.17.054 Short form manual
- (optional) fittings
- (optional) power supply
- (optional) Battery Pack
Measurement/control system:
- Flow range: 20.. 2000 mln/min (seem) Mass flow units In/min and SLM refer to normal operating conditions, i.e. 0°C (32°F) and 1013 mbar (14.7 psi)
- Accuracy: ± 2% RD for flow > 50% of max. capacity ± (1 % RD + 0.5% FS) on lower flows Technical specifications are based on Air at maximum FS
- Repeatability: < 0.2% FS typical
- Temperature rating: 0... 50(32... 122°F)
- Operating pressure: 0... 10bar(g)/0... 150psi(g)
- Pressure coefficient: ± 0,2% Rd/bar typical at Air
- Pre-installed gases: Air, N2,02, C02, CO, N20, AR, CH4, C3H8 and C4H10
- Standard calibration gas: Air, other gases are converted using our Fluidat® conversion model which will introduce extra inaccuracy
- Rangeability: up to 1:100
- Response time (sensor): (t63%) 2 seconds
- Temperature coefficient: Zero:
- Leak integrity, outboard: tested < 2 x 10-9 mbar l/s
- Attitude sensitivity: < 0,1 % FS
Mechanical parts:
- Material (wetted parts): Meter: aluminium, Viton (FPM) Needle Valve: Fluorosint, Brass, Buna N Controller: membrane Fiber-reinforced nitrile
- Test pressure: 21 bar{a)/300psi(a)
- Min.AP: 1 bar(d)
- Max.AP: 7 bar(d)
- Process connections: G 1/4" BSPP female (compression fittings optional)
- Seals: Viton8, PTFE, Fluorosint* Buna N; Controller membrane: fiber-reinforced nitrile
- Weight: 1,4 kg
- Ingress protection: IP40
- Control Accuracy: < 0,5-1% Rd/bar
Electrical properties:
- Power supply: +l5...24Vdc(+/-10%)
- Max. power consumption: approx 135 mA
- Analog output: 0...5Vdc
- EMC: EU declaration
- Digital Communication: RS232 / RS485 {Modbus RTU/ASCII)
- Min. And max. Relay contacts: switching current 0.5 A, 24 Vdc one side grounded (0 Vdc power)
- Electrical connection: 8-pin RJ-45 modular jack
The fields of application for MASS-VIEW® mass flow controllers are diverse:
- Burner Control (furnace construction)
- Welding (welding gas monitoring)
- Leak measurements (quality, environment)
- Coating (equipment construction)
- Regulation of gaseous atmospheres (biotechnology)
- Measurements of gas consumption (hospitals)
- Test equipment (production maintenance)
- Local preparation of a gas mixture
- Flow rate monitoring (laboratories)
- Cutting (steel sheets)
- Cost centre billing
- Analytical equipment
- Aeration / sparging (food products, ice cream / edible oils
- Blanketing (food)
- Fermentation (food, biotechnology, pharma)