Pre-installed ranges
Ranges: Flow range (relative Air)
- Range 1: 0.2 ln/min .. 20 ln/min (SLM)
- Range 2: 0.1 ln/min .. 10 ln/min (SLM)
- Range 3: 0.05 ln/min .. 5 ln/min (SLM)
- Range 4: 0.04 ln/min .. 2 ln/min (SLM)
Pre-installed gases
Gases: min. range .. max. range
- Air, N2, O2, CO2,CO and N2O: 0.04 .. 20 ln/min (SLM)
- Ar: 0.08 .. 40 ln/min (SLM)
- CH4, C3H8 and C4H10: 0.02 .. 10 ln/min (SLM)
- Clear indication in:
- actual flow rate (bar graph and value)
- desired flow units
- type of gas
- totalised flow
- Bright, wide-angle OLED display
- Free of parallax error
- Virtually independent of temperature and pressure variations
- Low pressure drop
- Wide flow ranges
- Fast response
- High accuracy
- Electronic output:
- Analog (0 .. 5 Vdc)
- RS-232 interface (with FLOWBUS)
- Modbus-RTU/ASCII interface
- Configurable password protection
- Alarm and counter functions
- Relays
- Multi Gas / Multi Range
- 4 Pre-installed gases
- Digitally calibrated
- Free software tools
- MASS-VIEW flow meter
- packing box
- 9.17.054 Short form manual
- (optional) fittings
- (optional) power supply
- (optional) Battery Pack
Please note:
Our mass flow meters are sold without fittings and without powersupply, please use the `Complementary products` tab to order additional accessories. For your convenience, we also have our flow ranges in other flow units.
Measurement / control system
- Flow range: 0.04 .. 20 ln/min (SLM) Mass flow units ln/min and SLM refer to normal operating conditions, i.e. 0°C (32°F) and 1013 mbar (14.7 psi)
- Accuracy: ± 2% RD for flow > 50% of max. capacity, ± (1% RD + 0.5% FS) on lower flows, Technical specifications are based on Air at maximum FS
- Repeatability: < 0.2% FS typical
- Operating pressure: 0 .. 10 bar(g) / 0 .. 150 psi(g)
- Pressure coefficient: 0.2% / bar typical at Air
- Pre-installed gases: Air, N2, O2, CO2, CO, N2O, Ar, CH4, C3H8 and C4H10
- Standard calibration gas: Air, other gases are converted using our Fluidat® conversion model which will introduce extra inaccuracy
- Rangeability: up to 1:100
- Response time (sensor): (t63%) 2 seconds
- Operating temperature: 0 .. 50°C (32 .. 122°F)
- Temperature coefficient: Zero: <0.1%FS/°C, Span: <0.2%RD/°C
- Leak integrity, outboard: < 1 x 10-9 mbar l/s He
- Attitude sensitivity: < 0.1% FS
Mechanical parts
- Material (wetted parts): Meter: aluminium, Viton® (FPM)
- Test pressure: 21 bar (a) / 300 psi (a)
- Process connections: G 1/4" BSPP female, (compression fittings optional)
- Seals: Viton®, PTFE
- Weight: 0.7 kg
- Ingress protection: IP-40
Electrical properties
- Power supply: +15 … 24 Vdc (+/- 10%)
- Max. power consumption: approx. 135 mA / 2W
- Analog output: 0 .. 5 Vdc
- EMC: EU declaration
- Digital Communication: RS232 / RS485 (Modbus-RTU/ASCII)
- Min. And max. Relay contacts: switching current 0.5 A, 24 Vdc, one side grounded (0 Vdc power)
- Electrical connection: 8-pin RJ-45 modular jack
The fields of application for MASS-VIEW® mass flow meters are diverse:
- Burner Control (furnace construction)
- Welding (welding gas monitoring)
- Leak measurements (quality, environment)
- Coating (equipment construction)
- Regulation of gaseous atmospheres (biotechnology)
- Measurements of gas consumption (hospitals)
- Test equipment (production maintenance)
- Local preparation of a gas mixture
- Flow rate monitoring (laboratories)
- Cutting (steel sheets)
- Cost centre billing
- Analytical equipment
- Aeration / sparging (food products, ice cream / edible oils
- Blanketing (food)
- Fermentation (food, biotechnology, pharma)