Chromatotec

MedorModel Exd -Sulfur Compounds / Mercaptans / Odor Analyzers

SHARE

Chromatotec has engineered and manufactured the new Medor Exd designed to operate in hazardous area environment zone 1 without any purging system.

Most popular related searches

The MEDOR Exd is an automatic and isothermal gas chromatograph dedicated to sulfur compounds analysis (H2S, mercaptans and sulphides) in different matrices.

Two versions exist :

  • the MEDOR Exd ppm which measures at ppm levels
  • the MEDOR Exd ppb which measures at ppb levels.
  • Hazardous area Ex enclosure 
  • Internal temperature and pressure monitoring
  • Loop injection by automatic valve
  • Detection is made by a gas-liquid reaction
  • Sulfur specific detector – no interferencees
  • The detector life is in excess of 10 years
  • ASTM D7493-08 : Standard Test Method for Online Measurement of Sulfur Compounds in Natural Gas and gaseous Fuels
  • Fully automatic, continuous online analyzer in an Ex enclosure
  • Integrated industrial computer
  • Storage of date & time stamped chromatograms

Chromatotec developed software system enables :

  • Remote monitoring & injection control
  • Full traceability with on board archiving of results
  • QC Set up and control of threshold alarms
  • Export of data MODBUS / MGS1 / 4-20mA / 0-10V

  • External multiple stream selector (up to 16 streams controlled by the analyzer)
  • Calculation modules (Average / Statistics / Odor index...)
  • Electric selection valve to reduce air consumption
  • 24 V DC power supply, can work on battery or solar panel
  • Inbuilt nitrogen generator for hazardous area from instrument air or from external compressor
  • Liquid Injection valve for LPG or up to condensate analysis
  • Sampling vavle for high concentration up to % level
  • Internal temperature control system using electric heater / VORTEX / electric peltier cooler
  • Speciation and/or total sulfur

Detection limits:

  • MEDOR® Exd ppm:
    • H2S: 0,1 ppm (0,14 mg/m3)
  • MEDOR® Exd ppb:
    • H2S: 5 ppb (7,0 μg/m3) or DMS: 2 ppb (5,1 μg/m3)

Range adjustable, depending on application:

  • 0/10 or 0/100 or 0/1000 ppm or ppb
  • Calculation: total sulfur, total mercaptans...

Relative Standard Deviation:

  • RSD < 3% on concentration over 48H.
  • RSD < 0.5% on retention time over 48H.

Cycle Time:

  • H2S 120 s
  • H2S/TOS/TS 120 s
  • THT 180s (if only THT)
  • H2S, MM, EM 300s
  • H2S, mercaptans, THT 720 s
  • H2S, mercaptans, THT 900 s with CALIB for validation of each analysis

Supervisor:

  • Embedd industrial computer Windows® based with LCD display
  • 128 GB of hardware storage on SSD memory

Communication:

  • MODBUS communication protocol
  • 4-20mA
  • Ethernet
  • 3G module (optional)

Gas supply for GC operation:

  • Carrier: zero air or N2 (3 bar): 4 ml/min. Use N2 if THT is present
  • CALIB: air or N2 50 ml/min
  • Sample inlet 1 bar: 80 ml/min
  • Pneumatic valve: 90 ml/commutation (0 ml in option)

Power supply:

  • Main: 230V / 115V or 50/60 Hz
  • 24 V DC in option

Electrical consumption:

  • 150 VA without options

Dimensions and Weight:

  • Height: 1900 mm
  • Width: 800 mm
  • Depth: 600 mm
  • Net weight of analyzer without frame: 105 kg (175 kg with frame)