Sulfurs / Mercaptans / odor analyzer: MEDOR Exp Chromatotec has engineered and manufactured the new Exp Medor designed to operate in hazardous area environment such as Class I, Division 2, group C&D and ATEX zone I and II.

Most popular related searches

The MEDOR Exp is an automatic and isothermal gas chromatograph dedicated to sulfur compounds analysis (H2S, mercaptans and sulphides) in different matrices.

Two versions exist :

  • the MEDOR Exp ppm which measures at ppm levels
  • the MEDOR Exp ppb which measures at ppb levels.
  • Hazardous area Ex enclosure 
  • Internal temperature and pressure monitoring
  • Loop injection by automatic valve
  • Detection is made by a gas-liquid reaction
  • Sulfur specific detector – no interferencees
  • The detector life is in excess of 10 years
  • ASTM D7493-08 : Standard Test Method for Online Measurement of Sulfur Compounds in Natural Gas and gaseous Fuels
  • Fully automatic, continuous online analyzer in an Ex enclosure
  • Integrated industrial computer
  • Storage of date & time stamped chromatograms

Chromatotec developed software system enables :

  • Remote monitoring & injection control
  • Full traceability with on board archiving of results
  • QC Set up and control of threshold alarms
  • Export of data MODBUS / MGS1 / 4-20mA / 0-10V
  • External multiple stream selector (up to 16 streams controlled by the analyzer)
  • Calculation modules (Average / Statistics / Odor index...)
  • Electric selection valve to reduce air consumption
  • 24 V DC power supply, can work on battery or solar panel
  • Vortex cooler (air consumption depending of external t°)
  • X - Purge for Zone 1
  • Inert purge with N2 for low consumption of purge gas with Xpurge (can work on N2 cylinders)
  • Internal electric heater and/or cooler for temperature regulation of the Exp cabinet with thermal insulation
  • Speciation and/or total sulfur

Detection limits:

  • MEDOR® Exp ppm:
    • H2S: 0,1 ppm (0,14 mg/m3)
  • MEDOR® Exp ppb:
    • H2S: 5 ppb (7,0 μg/m3) or DMS: 2 ppb (5,1 μg/m3)

Range adjustable, depending on application:

  • 0/10 or 0/100 or 0/1000 ppm or ppb
  • Calculation: total sulfur, total mercaptans...

Relative Standard Deviation:

  • RSD < 3% on concentration over 48H.
  • RSD < 0.5% on retention time over 48H.

Cycle Time:

  • H2S 120 s
  • H2S/TOS/TS 120 s
  • THT 180s (if only THT)
  • H2S, MM, EM 300s
  • H2S, mercaptans, THT 720 s
  • H2S, mercaptans, THT 900 s with CALIB for validation of each analysis

Supervisor:

  • Embedd industrial computer Windows® based with LCD display
  • 32 GB of hardware storage on SSD memory

Communication:

  • MODBUS communication protocol
  • 4-20mA
  • Ethernet
  • 3G module (optional)

Gas supply for GC operation:

  • Carrier: zero air or N2 (3 bar): 4 ml/min. Use N2 if THT is present
  • CALIB: air or N2 50 ml/min
  • Sample inlet 1 bar: 80 ml/min
  • Pneumatic valve: 90 ml/commutation (0 ml in option)

Gas supply for Exp cabinet:

  • If air used for dilution: 30 l/min in continue
  • If nitrogen used for dilution: 500 l to purge the cabinet and
  • < 0,5 l/min in continue to maintain overpressure

Power supply:

  • Main: 230V / 115V or 50/60 Hz
  • 24 V DC in option

Electrical consumption:

  • 150 VA without options

Dimensions and Weight:

  • Height: 800 mm
  • Width: 600 mm
  • Depth: 300 mm
  • Net weight: 40 kg