membraPure GmbH
membraPure - Model IONUS -Ion Chromatograph
FrommembraPure GmbH
Designed for the analysis of anions and cations: This IONUS is suitable for the analysis of anions and cations in research, development and everyday routine. The sample solutions are mostly water-based and may contain water-miscible organic solvents. A classic example is the analysis of (drinking) water according to EPA 300 Part A and B. The advantage of IONUS is the compatibility with IC columns of all manufacturers and is compatible with all common eluents of anion and cation chromatography.
Most popular related searches
UV-VIS detector
ion chromatograph
drinking water analysis
ion exchange chromatography
UV-VIS
conductivity detection
chromatography
isocratic pumps
organic solvent
conductivity detector
Using detection by conductivity
- Analysis of anions and cations
- Easy sample preparation
- Detection by conductivity
- Compatible with the common eluents and columns
- Compatibility with IC columns
- Online service functions for troubleshooting
Method
Ion exchange chromatpgraphy with in built conductivity detector
Optional with UV detection
Conductivity detection
Noise: 0.02 µS/1 s | range: 0 – 10 mS/cm
Reproducibility
0.1 % RSD at 100 µL/min

Manual injection port
Upon request each system can be supplied as manual configuration.
High pressure side prime and purge valves in eluent and reagent flow.
Based on chemical processregeneration of suppressors with acid.
Manual and automatic peak integration with integrated IQ/OQ procedure for software (only available with software Clarity).
The IONUS can be equipped with an additional UV/VIS detector.
Programmable thermostat for column (and suppressors).
- method: ion exchange chromatography of anions and cations in subsequent mode
- manual injection: 20 µL, further injection loops upon request (50 µL, 100 µL, 200 µL)
- autosampler: 2 racks, each of them with space for 48 vials (1.5 mL) or 12 vials (6 mL), sample cooling, loop 100 µL, 3 injection modes (full-loop, partial loop, microliter-pickup)
- column: stainless steel / PEEK
- temperature stability / range: ~ 0.5 °C / ambient up to 50 °C
- detection:
- conductivity detector:
- noise: 0.02 µS, 1s | linearity: < 1 s | range: 0 - 10 mS/cm
- effective cell volume: 1 µL, conductivity block: 30 °C
- isocratic pump system:
- max. pressure: 400 bar | flow rate: 0.01 - 10.00 mL/min
- reproducibility of flow rate: 0.1 % RSD at 100 µL/min
- maximum operating pressure: 120 bar
- control software & data aquisition: Clarity (21 CFR part 11 compliant) or AminoPeak
- dimensions, weight, power: 1000 x 350 x 375 mm*, 60 kg, 110 - 230 V, 50/60 Hz
*800 mm with opened main unit