This version of the MK-III has the gauge connected to the back of the MK-III. The advantage of this season is that the sensors are centralized in a single compact unit. This version of the MK-III has the gauge connected to the back of the MK-III. The advantage of this season is that the sensors are centralized in a single compact unit and does not need battery gauge. The only requirements are that the MK-III station is properly aligned vertically for adjusting the gauge.
Anemometer - wind speed
Scale: 0-67 meters / sec; 0-240 km / h; 0-130 knots.
Resolution: 1.0 unit
Accuracy: + -2% scale principle.
Veleta-Wind direction
Scale: II Display Oracle 16 points display with LED, while the direction comes from one point he led flashes indicating the current wind direction. With the CC2000 datalogger indicates the direction in degrees.
Example: 360 = North, SE = 220 ° ..... etc.
Temperature
Scale: from -54 to + 74 ° C; -66º To 166º F
Resolution: 1 whole unit at Oracle and tenths.
(0.1) in datalogger CC2000.
Accuracy: + -0.5 ° C, + - 1 ° F.
RH
Scale: 0 to 100% RH
Resolution: 1 unit.
Accuracy: + - 2% to 25ºC.Compensanción.
temperature-40C to + 85C.
Dew point
Scale: - 40 to + 60 ° C.
Resolution: 1 whole unit at Oracle and tenths.
(0.1) in datalogger CC2000.
Accuracy: + - 1 ° C, + -2 F.
Wind-chill factor
Scale: -80 ° C, 127 ° F.
Resolution: 1 whole unit at Oracle and decimas.
(0.2) in datalogger CC2000.
Accuracy: + -1 ° C, 1 ° F.
Barometer-Atmospheric Pressure:
Scale: from 551 to 1084 millibars (hPa).
Accuracy: + - 1.69 millibars (hPa) Compensation.
temperature 40 ° to 85 ° C.
Precipitation Pluviómetro-
Scale: Unlimited capacity, diameter of the mouth.
20.32cm rain gauge.
Resolution: 0.25 mm.
Accuracy: + - 2% to 25.4 mm / h.
Transmission
Range: 50 to 200 meters, depending on the location and structure of the walls.
Transmission frequency: 433MHz. Certified CE, FCC.
Antenna: omnidireccionable Integrated.
Agency consulted: CTMS Cambridge Test & Mesurament.
Services Ltd.
Measurements
C ensor MKIII-WS2000, Interface, solar panel: 25x38x71 cm.
Scale: 0-67 meters / sec; 0-240 km / h; 0-130 knots.
Resolution: 1.0 unit
Accuracy: + -2% scale principle.
Veleta-Wind direction
Scale: II Display Oracle 16 points display with LED, while the direction comes from one point he led flashes indicating the current wind direction. With the CC2000 datalogger indicates the direction in degrees.
Example: 360 = North, SE = 220 ° ..... etc.
Temperature
Scale: from -54 to + 74 ° C; -66º To 166º F
Resolution: 1 whole unit at Oracle and tenths.
(0.1) in datalogger CC2000.
Accuracy: + -0.5 ° C, + - 1 ° F.
RH
Scale: 0 to 100% RH
Resolution: 1 unit.
Accuracy: + - 2% to 25ºC.Compensanción.
temperature-40C to + 85C.
Dew point
Scale: - 40 to + 60 ° C.
Resolution: 1 whole unit at Oracle and tenths.
(0.1) in datalogger CC2000.
Accuracy: + - 1 ° C, + -2 F.
Wind-chill factor
Scale: -80 ° C, 127 ° F.
Resolution: 1 whole unit at Oracle and decimas.
(0.2) in datalogger CC2000.
Accuracy: + -1 ° C, 1 ° F.
Barometer-Atmospheric Pressure:
Scale: from 551 to 1084 millibars (hPa).
Accuracy: + - 1.69 millibars (hPa) Compensation.
temperature 40 ° to 85 ° C.
Precipitation Pluviómetro-
Scale: Unlimited capacity, diameter of the mouth.
20.32cm rain gauge.
Resolution: 0.25 mm.
Accuracy: + - 2% to 25.4 mm / h.
Transmission
Range: 50 to 200 meters, depending on the location and structure of the walls.
Transmission frequency: 433MHz. Certified CE, FCC.
Antenna: omnidireccionable Integrated.
Agency consulted: CTMS Cambridge Test & Mesurament.
Services Ltd.
Measurements
C ensor MKIII-WS2000, Interface, solar panel: 25x38x71 cm.