Elmetron Sp. j.
  1. Companies
  2. Elmetron Sp. j.
  3. Products
  4. Model CPI-502 - Laboratory Ph / Ion ...

Model CPI-502 -Laboratory Ph / Ion Meter

SHARE

CPI-502 measures pH, redox potential (mV), ion concentration and temperature. Enables simultameous ion selective measurement of chosen ion, pH or mV and temperature. The chosen measuring function may be viewed by pressing an appropriate button. The most recent model has been improved with more possibilities providing easier operation.

Most popular related searches
  • Measures accurately: pH, redox potential, ion concentration in pX, g/l, M/l, or ppm and temperature (°C).
  • The meter is equipped with built-in 60 mm thermal printer.
  • The display enables simultaneous readout of the measured function and temperature.
  • Calibration of the pH and ION electrodes (ISE) in 1 to 5 points.
  • In the pH function automatic correction of the pH standard solution value changes, along with the temperature changes for NIST standards.
  • In the ION measurement function molar weight and valence of the measured ion is automatically introduced after choosing the ion.
  • Automatic conversion of units – e.g. M/l to mg/l.
  • Memory of 4000 results.
  • USB output
  • Highly accurate measurement in each function.
  • Easy parameter setting.
  • The meter is equipped with built-in 60 mm thermal printer.
  • Standardised procedures for pH and ion selective measurement facilitate working.
  • “HOLD” function to freeze the result on the display.
  • Signalisation of the result stabilisation with the “READY” symbol and a sound.
  • Possibility of sending a calibration report to a PC - up to 10 last calibrations.
  • Calibration of the pH electrode: 1 ÷ 5 points.
  • Automatic pH buffer detection, their value may be set by the user.
  • Automatic correction of the stored pH standard value influenced by the temperature change (compliant with NIST), what eliminates the necessity of the temperature adjustment.
  • Storage of 3 electrodes calibration parameters enables quick replacement.
  • Possibility to view the electrode`s characteristics.
  • Depending on type of the chosen electrode making measurement in pure water, sewage, pastes, etc. is possible.
  • Isolated connectors for pH and ion selective electrode enable their simultaneous connection and measurements in one vessel.
  • Automatic evaluation of the electrode condition.
  • Readout of the pH electrode condition and data – the zero offset and slope percentage may be checked.